An improved straight-line fitting method for analyzing pumping test recovery data
Theis (1935) derived an exact solution for the residual drawdown in a well after the cessation of a pumping test by summing two drawdowns: one (s1), caused by imaginary continuation of the original pumping and the other (s2), due to an imaginary injection at the same constant rate. We approximated t...
Veröffentlicht in: | Ground water. - 1979. - 43(2005), 6 vom: 12. Nov., Seite 939-42 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
2005
|
Zugriff auf das übergeordnete Werk: | Ground water |
Schlagworte: | Journal Article Research Support, Non-U.S. Gov't |