Evaluation of an ultrasonic echo-tracking method for measurements of arterial wall movements in two dimensions

The longitudinal movement of blood vessel walls has so far gained little or no attention, as it has been presumed that these movements are of a negligible magnitude. However, modern high-resolution ultrasound scanners can demonstrate that the inner layers of the arterial wall exhibit considerable mo...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 52(2005), 8 vom: 08. Aug., Seite 1300-11
1. Verfasser: Cinthio, Magnus (VerfasserIn)
Weitere Verfasser: Ahlgren, Asa Rydén, Jansson, Tomas, Eriksson, Anders, Persson, Hans W, Lindström, Kjell
Format: Aufsatz
Sprache:English
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Evaluation Study Journal Article Research Support, Non-U.S. Gov't Validation Study
LEADER 01000naa a22002652 4500
001 NLM158544986
003 DE-627
005 20231223082416.0
007 tu
008 231223s2005 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0529.xml 
035 |a (DE-627)NLM158544986 
035 |a (NLM)16245599 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cinthio, Magnus  |e verfasserin  |4 aut 
245 1 0 |a Evaluation of an ultrasonic echo-tracking method for measurements of arterial wall movements in two dimensions 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 29.11.2005 
500 |a Date Revised 10.12.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a The longitudinal movement of blood vessel walls has so far gained little or no attention, as it has been presumed that these movements are of a negligible magnitude. However, modern high-resolution ultrasound scanners can demonstrate that the inner layers of the arterial wall exhibit considerable movements in the longitudinal direction. This paper evaluates a new, noninvasive, echo-tracking technique, which simultaneously can track both the radial and the longitudinal movements of the arterial wall with high resolution in vivo. Initially, the method is evaluated in vitro using a specially designed ultrasound phantom, which is attached to and moved by an X-Y system, the movement of which was compared with two high-resolution triangulation lasers. The results show an inaccuracy of 2.5% full scale deflection (fsd), reproducibility of 12 microm and a resolution of 5 microm, which should be more than sufficient for in vivo studies. The ability of the method is also demonstrated in a limited in vivo study in which a preselected part of the inner vessel wall of the right common carotid artery of a healthy volunteer is tracked in two dimensions over many cardiac cycles. The results show well reproducible x-y movement loops in which the recorded radial and longitudinal movements both are of the magnitude millimetre 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Validation Study 
700 1 |a Ahlgren, Asa Rydén  |e verfasserin  |4 aut 
700 1 |a Jansson, Tomas  |e verfasserin  |4 aut 
700 1 |a Eriksson, Anders  |e verfasserin  |4 aut 
700 1 |a Persson, Hans W  |e verfasserin  |4 aut 
700 1 |a Lindström, Kjell  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 52(2005), 8 vom: 08. Aug., Seite 1300-11  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:52  |g year:2005  |g number:8  |g day:08  |g month:08  |g pages:1300-11 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 52  |j 2005  |e 8  |b 08  |c 08  |h 1300-11