Multi-wavelength fluorometry for anaerobic digestion process monitoring

Applicability of multi-wavelength fluorometry for anaerobic digestion process monitoring was investigated in a 3.5 L upflow anaerobic sludge bed (UASB) lab-scale reactor. Both off-line and on-line monitoring of key process parameters was tested. Off-line emission spectra were measured at an angle of...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 52(2005), 1-2 vom: 30., Seite 465-71
1. Verfasser: Morel, E (VerfasserIn)
Weitere Verfasser: Santamaria, K, Perrier, M, Guiot, S R, Tartakovsky, B
Format: Aufsatz
Sprache:English
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Fatty Acids, Volatile Sewage
LEADER 01000naa a22002652 4500
001 NLM157935590
003 DE-627
005 20231223081209.0
007 tu
008 231223s2005 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0527.xml 
035 |a (DE-627)NLM157935590 
035 |a (NLM)16180465 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Morel, E  |e verfasserin  |4 aut 
245 1 0 |a Multi-wavelength fluorometry for anaerobic digestion process monitoring 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 08.11.2005 
500 |a Date Revised 15.11.2006 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Applicability of multi-wavelength fluorometry for anaerobic digestion process monitoring was investigated in a 3.5 L upflow anaerobic sludge bed (UASB) lab-scale reactor. Both off-line and on-line monitoring of key process parameters was tested. Off-line emission spectra were measured at an angle of 90 degrees to the excitation beam using a cuvette. On-line measurements were carried out using a fiber optic probe in the external recirculation line of the digester. Fluorescence spectra were correlated to available analytical measurements to obtain partial least square regression models. An independent set of measurements was used to validate the regression models. Model estimations showed reasonable agreement with analytical measurements with multiple determination coefficients (R2) between 0.6 and 0.95. Results showed that offline fluorescence measurements can be used for fast estimation of anaerobic digestor effluent quality. At the same time, the on-line implementation of multi-wavelength fluorescence measurements can be used for realtime process monitoring and, potentially, for on-line process control 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Fatty Acids, Volatile  |2 NLM 
650 7 |a Sewage  |2 NLM 
700 1 |a Santamaria, K  |e verfasserin  |4 aut 
700 1 |a Perrier, M  |e verfasserin  |4 aut 
700 1 |a Guiot, S R  |e verfasserin  |4 aut 
700 1 |a Tartakovsky, B  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 52(2005), 1-2 vom: 30., Seite 465-71  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:52  |g year:2005  |g number:1-2  |g day:30  |g pages:465-71 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 52  |j 2005  |e 1-2  |b 30  |h 465-71