100 |
1 |
|
|a Friedrichs, Kristen R
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Using an independent quality control software program, EZ Runs, to monitor quality control procedures for a bench-top coagulation analyzer
|
264 |
|
1 |
|c 2005
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ohne Hilfsmittel zu benutzen
|b n
|2 rdamedia
|
338 |
|
|
|a Band
|b nc
|2 rdacarrier
|
500 |
|
|
|a Date Completed 28.03.2006
|
500 |
|
|
|a Date Revised 09.11.2019
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a BACKGROUND: Comprehensive quality control (QC) procedures are necessary to ensure accurate analytic method performance. Highly automated systems typically have inherent QC programs that facilitate performance and maintenance of QC procedures; however, for bench-top analyzers that lack internal systems, independent QC programs must be used
|
520 |
|
|
|a OBJECTIVE: The goal of this study was to evaluate the adaptability of an independent QC program, EZ Runs (Westgard QC Inc, Madison, WI, USA), to the maintenance of QC procedures for a mechanical, bench-top coagulation unit and to compare the results with our current, manual, QC method in a qualitative way
|
520 |
|
|
|a METHODS: A QC application file for activated partial thromboplastin time (aPTT) performed on a STart4 (Diagnostica Stago, Parsippany, NJ) was created in EZ Runs. Results were recorded and interpreted using this software package as well as the current, manual, QC method
|
520 |
|
|
|a RESULTS: EZ Runs was adaptable to QC monitoring for the bench-top analyzer, and the program permitted identification of both random and systematic errors not detected by the manual QC system
|
520 |
|
|
|a CONCLUSIONS: EZ Runs improved the performance and maintenance of QC procedures for this bench-top coagulation analyzer. The results indicated the need to improve staff training in assay performance and QC interpretation. In addition, use of the software program indicated that a multirule QC design was needed to monitor assay performance
|
650 |
|
4 |
|a Journal Article
|
700 |
1 |
|
|a Young, Karen M
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Veterinary clinical pathology
|d 1975
|g 34(2005), 3 vom: 21. Sept., Seite 218-23
|w (DE-627)NLM098159984
|x 0275-6382
|7 nnns
|
773 |
1 |
8 |
|g volume:34
|g year:2005
|g number:3
|g day:21
|g month:09
|g pages:218-23
|