High-energy phase-contrast X-ray imaging using a two-crystal X-ray interferometer

To broaden the scope of phase-contrast X-ray imaging in biomedical applications, the energy of X-rays in a large-area imaging system using a two-crystal X-ray interferometer has been increased from 17.7 keV to 35 keV. The use of higher-energy X-rays makes it possible to observe larger samples having...

Description complète

Détails bibliographiques
Publié dans:Journal of synchrotron radiation. - 1994. - 12(2005), Pt 4 vom: 21. Juli, Seite 534-6
Auteur principal: Yoneyama, Akio (Auteur)
Autres auteurs: Takeda, Tohoru, Tsuchiya, Yoshinori, Wu, Jin, Lwin, Thet Thet, Hyodo, Kazuyuki, Hirai, Yasuharu
Format: Article
Langue:English
Publié: 2005
Accès à la collection:Journal of synchrotron radiation
Sujets:Evaluation Study Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652c 4500
001 NLM156077353
003 DE-627
005 20250206115538.0
007 tu
008 231223s2005 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0520.xml 
035 |a (DE-627)NLM156077353 
035 |a (NLM)15968135 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yoneyama, Akio  |e verfasserin  |4 aut 
245 1 0 |a High-energy phase-contrast X-ray imaging using a two-crystal X-ray interferometer 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 23.08.2005 
500 |a Date Revised 10.12.2019 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a To broaden the scope of phase-contrast X-ray imaging in biomedical applications, the energy of X-rays in a large-area imaging system using a two-crystal X-ray interferometer has been increased from 17.7 keV to 35 keV. The use of higher-energy X-rays makes it possible to observe larger samples having greater variation in density within shorter measurement periods, at higher spatial resolution, and at lower X-ray doses. After optimizing the imaging system for 35 keV X-rays, a 25 mm x 30 mm interference pattern with 50% visibility was generated at the Photon Factory. The system's capabilities are demonstrated by this pattern and a high-quality three-dimensional image of a rat heart 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Takeda, Tohoru  |e verfasserin  |4 aut 
700 1 |a Tsuchiya, Yoshinori  |e verfasserin  |4 aut 
700 1 |a Wu, Jin  |e verfasserin  |4 aut 
700 1 |a Lwin, Thet Thet  |e verfasserin  |4 aut 
700 1 |a Hyodo, Kazuyuki  |e verfasserin  |4 aut 
700 1 |a Hirai, Yasuharu  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 12(2005), Pt 4 vom: 21. Juli, Seite 534-6  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:12  |g year:2005  |g number:Pt 4  |g day:21  |g month:07  |g pages:534-6 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 12  |j 2005  |e Pt 4  |b 21  |c 07  |h 534-6