Applying interventional treatment for the atrial septal defect in 165 children under five years of age

OBJECTIVE: To study the clinical technology of transcatheter closure of secundum atrial septal defects (ASD) with Amplatzer device in younger and lower body weight children

Bibliographische Detailangaben
Veröffentlicht in:Zhonghua er ke za zhi = Chinese journal of pediatrics. - 1960. - 43(2005), 5 vom: 30. Mai, Seite 373-6
1. Verfasser: Wang, Hui-shen (VerfasserIn)
Weitere Verfasser: Qian, Ming-yang, Zhang, Zhi-wei, Zeng, Shao-ying, Xie, Yu-mei, Li, Yu-fen
Format: Aufsatz
Sprache:Chinese
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:Zhonghua er ke za zhi = Chinese journal of pediatrics
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM155671103
003 DE-627
005 20250206104508.0
007 tu
008 231223s2005 xx ||||| 00| ||chi c
028 5 2 |a pubmed25n0519.xml 
035 |a (DE-627)NLM155671103 
035 |a (NLM)15924757 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a chi 
100 1 |a Wang, Hui-shen  |e verfasserin  |4 aut 
245 1 0 |a Applying interventional treatment for the atrial septal defect in 165 children under five years of age 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 04.05.2010 
500 |a Date Revised 24.11.2016 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a OBJECTIVE: To study the clinical technology of transcatheter closure of secundum atrial septal defects (ASD) with Amplatzer device in younger and lower body weight children 
520 |a METHODS: The transcatheter closure of ASD using Amplatzer septal occluder (ASO) was performed in 165 children under 5 years of age (75 boys and 90 girls) with secundum ASD from Aug 1998 to May 2004. The age of the cases ranged from 2 to 5 (mean 3.7 +/- 1.1) years. The body weight ranged from 9 to 18 (mean 12.6 +/- 2.3) kg. The ratio of pulmonary circulation quantity to the systemic circulation quantity (Qp/Qs) was 3.2 +/- 1.9. All the patients underwent clinical examination, X-ray, electrocardiography (ECG) and echocardiography (Echo) for diagnosis of secundum ASD. The transthoracic echocardiography (TTE) was used to detect and measure the defect of the patients and even trans-esophageal echocardiography (TEE) had to be used when it was necessary. With Echo and X-ray guidance, the measuring balloon was used in the body and outside the body to determine the balloon-stretch diameters of ASD, and proper occluders were selected accordingly for the patients for interventional treatment of ASD 
520 |a RESULTS: The devices were implanted successfully in 163 (98.8%) cases. One failure occurred in a case in whom the device moved into the left atrium after release, and the other failure was that the position of the device was uncertain because of temporary unavailability of a special transducer for TEE. Surgical operations were performed for these two cases. The stretch diameter of ASD was from (8 - 30) mm, (mean 18.3 +/- 5.1) mm. The size of device was selected according to the stretch diameter of ASD. The diameter of the occluders selected was from (8 - 30), (mean 18.6 +/- 5) mm in this series. The occlusion procedure was monitored by fluoroscopy and TTE and in 5 cases (3%) by TEE. The diameter of right ventricle was improved within 2 days after occlusion from (mean 16.4 +/- 4.9) mm to (mean 12.6 +/- 3.8) mm, (p < 0.01). One hundred and forty seven cases belonged to the simple secundum ASD(89%). Thirteen cases who were complicated with other cardiac deformity were treated successfully with different interventional procedure. Six cases had multiple openings and three of these cases had tumour-like changes of the atrial septum which were closed completely just by one occluder. In only one case small quantity of residual shunt remains. No other severe complication was found in this group. About 100 cases (60%) had large ASD, so the procedure was more difficult in those cases 
520 |a CONCLUSION: The clinical effectiveness of treatment of ASD in children under 5 years of age with Amplatzer occluders was satisfactory and therefore this therapeutic procedure is feasible for this age group of patients. Nevertheless, we do not recommend to use the technique for infants and children under 2 years of age. Strict selection of indications and proper size of occluder and good cardiologic and surgical settings are among the basic factors for successful interventional occlusion of ASD in young children 
650 4 |a Journal Article 
700 1 |a Qian, Ming-yang  |e verfasserin  |4 aut 
700 1 |a Zhang, Zhi-wei  |e verfasserin  |4 aut 
700 1 |a Zeng, Shao-ying  |e verfasserin  |4 aut 
700 1 |a Xie, Yu-mei  |e verfasserin  |4 aut 
700 1 |a Li, Yu-fen  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Zhonghua er ke za zhi = Chinese journal of pediatrics  |d 1960  |g 43(2005), 5 vom: 30. Mai, Seite 373-6  |w (DE-627)NLM136249191  |x 0578-1310  |7 nnns 
773 1 8 |g volume:43  |g year:2005  |g number:5  |g day:30  |g month:05  |g pages:373-6 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_11 
912 |a GBV_ILN_20 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_39 
912 |a GBV_ILN_40 
912 |a GBV_ILN_50 
912 |a GBV_ILN_61 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_72 
912 |a GBV_ILN_120 
912 |a GBV_ILN_130 
912 |a GBV_ILN_227 
912 |a GBV_ILN_244 
912 |a GBV_ILN_285 
912 |a GBV_ILN_294 
912 |a GBV_ILN_350 
912 |a GBV_ILN_665 
912 |a GBV_ILN_813 
951 |a AR 
952 |d 43  |j 2005  |e 5  |b 30  |c 05  |h 373-6