Direct comparison of atomic force microscopic and total internal reflection microscopic measurements in the presence of nonadsorbing polyelectrolytes

We have investigated the structural and depletion forces between silica glass surfaces in aqueous, salt-free solutions of sodium poly(styrene sulfonate). The interaction forces were investigated by two techniques: total internal reflectance microscopy (TIRM) and colloid probe atomic force microscopy...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Langmuir : the ACS journal of surfaces and colloids. - 1992. - 21(2005), 12 vom: 07. Juni, Seite 5421-8
1. Verfasser: Biggs, Simon (VerfasserIn)
Weitere Verfasser: Prieve, Dennis C, Dagastine, Raymond R
Format: Aufsatz
Sprache:English
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:Langmuir : the ACS journal of surfaces and colloids
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM155668714
003 DE-627
005 20231223072620.0
007 tu
008 231223s2005 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0519.xml 
035 |a (DE-627)NLM155668714 
035 |a (NLM)15924471 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Biggs, Simon  |e verfasserin  |4 aut 
245 1 0 |a Direct comparison of atomic force microscopic and total internal reflection microscopic measurements in the presence of nonadsorbing polyelectrolytes 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 28.07.2006 
500 |a Date Revised 31.05.2005 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a We have investigated the structural and depletion forces between silica glass surfaces in aqueous, salt-free solutions of sodium poly(styrene sulfonate). The interaction forces were investigated by two techniques: total internal reflectance microscopy (TIRM) and colloid probe atomic force microscopy (AFM). The TIRM technique measures the potential energy of interaction directly, while the AFM is a force balance. Comparison between the data sets was used to independently calibrate the AFM data since the separation distances cannot be unequivocally determined by this technique. Oscillatory structural forces are excellent for this work since they give multiple reference points against which to analyze. Comparison of the data from the two techniques highlighted significant uncertainties in the AFM data. At low polymer concentrations, a significant uncertainty in the apparent zero separation distance was seen as a result of the AFM cantilever reaching an apparent constant compliance region prior to any real contact between the surfaces. Further complications arising from the number and position of the measured minima were also seen in the dilute polymer concentration regime as a result of hydrodynamic drainage between the approaching surfaces in the AFM perturbing the delicate structural components in the fluid 
650 4 |a Journal Article 
700 1 |a Prieve, Dennis C  |e verfasserin  |4 aut 
700 1 |a Dagastine, Raymond R  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Langmuir : the ACS journal of surfaces and colloids  |d 1992  |g 21(2005), 12 vom: 07. Juni, Seite 5421-8  |w (DE-627)NLM098181009  |x 1520-5827  |7 nnns 
773 1 8 |g volume:21  |g year:2005  |g number:12  |g day:07  |g month:06  |g pages:5421-8 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_350 
912 |a GBV_ILN_721 
951 |a AR 
952 |d 21  |j 2005  |e 12  |b 07  |c 06  |h 5421-8