Validation of the Nova CRT8 for the measurement of ionized magnesium in feline serum

BACKGROUND: Evaluation of serum magnesium (Mg) concentration is becoming important in human and veterinary critical care medicine. An ion-selective electrode can measure the physiologically active ionized fraction

Bibliographische Detailangaben
Veröffentlicht in:Veterinary clinical pathology. - 1975. - 34(2005), 2 vom: 27. Juni, Seite 124-31
1. Verfasser: Gilroy, Cornelia V (VerfasserIn)
Weitere Verfasser: Burton, Shelley A, Horney, Barbara S, Mackenzie, Allan L
Format: Aufsatz
Sprache:English
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:Veterinary clinical pathology
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Validation Study Magnesium I38ZP9992A
LEADER 01000naa a22002652 4500
001 NLM155460064
003 DE-627
005 20231223072157.0
007 tu
008 231223s2005 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0518.xml 
035 |a (DE-627)NLM155460064 
035 |a (NLM)15902663 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Gilroy, Cornelia V  |e verfasserin  |4 aut 
245 1 0 |a Validation of the Nova CRT8 for the measurement of ionized magnesium in feline serum 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 20.07.2005 
500 |a Date Revised 10.12.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a BACKGROUND: Evaluation of serum magnesium (Mg) concentration is becoming important in human and veterinary critical care medicine. An ion-selective electrode can measure the physiologically active ionized fraction 
520 |a OBJECTIVES: The purpose of this study was to validate an ion-specific electrode analyzer and assay for measuring ionized Mg in feline serum and to determine a reference interval for this analyte in cats 
520 |a METHODS: Venous blood samples were collected anaerobically from clinically healthy cats, and the serum was used to validate the analyzer and assay. This included investigating the stability of samples stored at different temperatures, intra- and interassay precision, linearity, analytical sensitivity, and potential interferences from bilirubin, lipemia, hemoglobin, or serum separator tubes. A reference interval was calculated 
520 |a RESULTS: Serum samples evaluated for ionized Mg concentrations can be stored at 20 degrees C for < or =24 hours, at 4 degrees C for < or =72 hours, and at 20 degrees C for < or =4 weeks, when samples are minimally exposed to air. Intra- and interassay precisions had coefficients of variation (CVs) of 1.23% and 2.02%, respectively. There was good linearity using serum (r = .998; y = -0.0057 + 1.0256x) and manufacturer-supplied aqueous solutions and quality control materials (r = .999; y = 0.0110 + 0.9213x). Apparent analytical sensitivity was at least 0.015 mmol/L. Mean recovery was good for ionized Mg in samples with 1+ icterus (104%), 4+ lipemia (99.3%) and 1-4+ hemolysis (98.6%). There was no significant difference (P = .52) in ionized Mg concentrations in serum collected in tubes containing no additives compared with serum collected in glass separator tubes. The serum ionized Mg reference interval was 0.47-0.63 mmol/L (n = 40) 
520 |a CONCLUSIONS: The Nova CRT8 analyzer and assay provide a precise and reliable method of measuring ionized Mg concentration in feline serum. Strict adherence to sampling techniques, handling, and storage are necessary for reliable results 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Validation Study 
650 7 |a Magnesium  |2 NLM 
650 7 |a I38ZP9992A  |2 NLM 
700 1 |a Burton, Shelley A  |e verfasserin  |4 aut 
700 1 |a Horney, Barbara S  |e verfasserin  |4 aut 
700 1 |a Mackenzie, Allan L  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Veterinary clinical pathology  |d 1975  |g 34(2005), 2 vom: 27. Juni, Seite 124-31  |w (DE-627)NLM098159984  |x 1939-165X  |7 nnns 
773 1 8 |g volume:34  |g year:2005  |g number:2  |g day:27  |g month:06  |g pages:124-31 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 34  |j 2005  |e 2  |b 27  |c 06  |h 124-31