ID22 : a multitechnique hard X-ray microprobe beamline at the European Synchrotron Radiation Facility

The ID22 beamline is dedicated to hard X-ray microanalysis allowing the combination of fluorescence, spectroscopy, diffraction and tomography techniques in a wide energy range from 6 to 70 keV. The recent installation of an in-vacuum undulator, a new sample stage and the adaptation of various focusi...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 12(2005), Pt 2 vom: 23. März, Seite 208-15
1. Verfasser: Somogyi, A (VerfasserIn)
Weitere Verfasser: Tucoulou, R, Martinez-Criado, G, Homs, A, Cauzid, J, Bleuet, P, Bohic, S, Simionovici, A
Format: Aufsatz
Sprache:English
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Air Pollutants
LEADER 01000naa a22002652 4500
001 NLM153849649
003 DE-627
005 20231223064833.0
007 tu
008 231223s2005 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0513.xml 
035 |a (DE-627)NLM153849649 
035 |a (NLM)15728973 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Somogyi, A  |e verfasserin  |4 aut 
245 1 0 |a ID22  |b a multitechnique hard X-ray microprobe beamline at the European Synchrotron Radiation Facility 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 20.04.2005 
500 |a Date Revised 21.11.2008 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a The ID22 beamline is dedicated to hard X-ray microanalysis allowing the combination of fluorescence, spectroscopy, diffraction and tomography techniques in a wide energy range from 6 to 70 keV. The recent installation of an in-vacuum undulator, a new sample stage and the adaptation of various focusing optics has contributed to a great improvement in the capabilities of the beamline, which is now accessed by a wide user community issued from medical, earth and environmental science, archaeology and material science. Many applications requiring low detection limits for localization/speciation of trace elements together with structural analysis have been developed at the beamline on the (sub)micrometer scale. The possibility of combining simultaneously different analytical probes offers the opportunity of a thorough study of a given sample or scientific problem. This paper presents a review of the recent developments of the beamline and a detailed description of its capabilities through examples from different fields of applications 
650 4 |a Journal Article 
650 7 |a Air Pollutants  |2 NLM 
700 1 |a Tucoulou, R  |e verfasserin  |4 aut 
700 1 |a Martinez-Criado, G  |e verfasserin  |4 aut 
700 1 |a Homs, A  |e verfasserin  |4 aut 
700 1 |a Cauzid, J  |e verfasserin  |4 aut 
700 1 |a Bleuet, P  |e verfasserin  |4 aut 
700 1 |a Bohic, S  |e verfasserin  |4 aut 
700 1 |a Simionovici, A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 12(2005), Pt 2 vom: 23. März, Seite 208-15  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:12  |g year:2005  |g number:Pt 2  |g day:23  |g month:03  |g pages:208-15 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 12  |j 2005  |e Pt 2  |b 23  |c 03  |h 208-15