CCD-based X-ray area detector for time-resolved diffraction experiments

A fast X-ray area detector for diffraction, scattering and imaging experiments at microsecond to millisecond time resolution has been developed. The key element of the detector is a fast (291 frames s(-1)) framing camera with three CCDs. A prism forms identical images on the CCDs and the frame rate...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 11(2004), Pt 6 vom: 01. Nov., Seite 456-61
1. Verfasser: Yagi, Naoto (VerfasserIn)
Weitere Verfasser: Inoue, Katsuaki, Oka, Toshihiko
Format: Aufsatz
Sprache:English
Veröffentlicht: 2004
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Evaluation Study Journal Article Research Support, Non-U.S. Gov't
LEADER 01000naa a22002652 4500
001 NLM151674671
003 DE-627
005 20231223060439.0
007 tu
008 231223s2004 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0506.xml 
035 |a (DE-627)NLM151674671 
035 |a (NLM)15496732 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Yagi, Naoto  |e verfasserin  |4 aut 
245 1 0 |a CCD-based X-ray area detector for time-resolved diffraction experiments 
264 1 |c 2004 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 21.12.2004 
500 |a Date Revised 10.12.2019 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a A fast X-ray area detector for diffraction, scattering and imaging experiments at microsecond to millisecond time resolution has been developed. The key element of the detector is a fast (291 frames s(-1)) framing camera with three CCDs. A prism forms identical images on the CCDs and the frame rate is increased three times by reading them alternately. In order to convert X-rays into visible light that is detectable with the CCDs, an X-ray image intensifier is used. The camera can also be used with a high-resolution X-ray detector. In both cases it was found to be important to use a phosphor with a short decay time to fully make use of the high-speed framing capability of the camera. Preliminary results of a fibre diffraction experiment on a skeletal muscle and coronary angiography are presented 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Inoue, Katsuaki  |e verfasserin  |4 aut 
700 1 |a Oka, Toshihiko  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 11(2004), Pt 6 vom: 01. Nov., Seite 456-61  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:11  |g year:2004  |g number:Pt 6  |g day:01  |g month:11  |g pages:456-61 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 11  |j 2004  |e Pt 6  |b 01  |c 11  |h 456-61