|
|
|
|
LEADER |
01000caa a22002652c 4500 |
001 |
NLM149821808 |
003 |
DE-627 |
005 |
20250205180843.0 |
007 |
tu |
008 |
231223s2004 xx ||||| 00| ||eng c |
028 |
5 |
2 |
|a pubmed25n0500.xml
|
035 |
|
|
|a (DE-627)NLM149821808
|
035 |
|
|
|a (NLM)15301511
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Yuan, Ruo
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Ultrasensitive potentiometric immunosensor based on SA and OCA techniques for immobilization of HBsAb with colloidal Au and polyvinyl butyral as matrixes
|
264 |
|
1 |
|c 2004
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ohne Hilfsmittel zu benutzen
|b n
|2 rdamedia
|
338 |
|
|
|a Band
|b nc
|2 rdacarrier
|
500 |
|
|
|a Date Completed 09.06.2006
|
500 |
|
|
|a Date Revised 21.11.2013
|
500 |
|
|
|a published: Print
|
500 |
|
|
|a Citation Status MEDLINE
|
520 |
|
|
|a A novel potentiometric immunosensor for detection of hepatitis B surface antigen (HBsAg) has been developed by means of self-assembly (SA) and opposite-charged adsorption (OCA) techniques to immobilize hepatitis B surface antibody (HBsAb) on a platinum electrode. A cleaned platinum electrode was first pretreated in the presence of 10% HNO3 and 2.5% K2CrO4 solution and held at -1.5 V (vs SCE) for 1 min to make it negatively charged and then immersed in a mixing solution containing hepatitis B surface antibody, colloidal gold (Au), and polyvinyl butyral (PVB). Finally, HBsAb was successfully immobilized onto the surface of the negatively charged platinum electrode modified nanosized gold and PVB sol-gel matrixes. The modified procedure was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The immobilized hepatitis B surface antibody exhibited direct electrochemical behavior toward hepatitis B surface antigen (HBsAg). The performance and factors influencing the performance of the resulting immunosensor were studied in detail. More than 95.7% of the results of the human serum samples obtained by this method were in agreement with those obtained by enzyme-linked immunosorbent assays (ELISAs). The resulting immunosensor exhibited fast potentiometric response (<3 min) to HBsAg. The detection limit of the immunosensor was 2.3 ng.mL(-1), and the linear range was from 8 to 1280 ng.mL(-1). Moreover, the studied immunosensor exhibited high sensitivity, good reproducibility, and long-term stability (>6 months)
|
650 |
|
4 |
|a Journal Article
|
650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
650 |
|
7 |
|a Colloids
|2 NLM
|
650 |
|
7 |
|a Hepatitis B Antibodies
|2 NLM
|
650 |
|
7 |
|a Polyvinyls
|2 NLM
|
650 |
|
7 |
|a Platinum
|2 NLM
|
650 |
|
7 |
|a 49DFR088MY
|2 NLM
|
650 |
|
7 |
|a Gold
|2 NLM
|
650 |
|
7 |
|a 7440-57-5
|2 NLM
|
650 |
|
7 |
|a polyvinylbutyral
|2 NLM
|
650 |
|
7 |
|a 9003-62-7
|2 NLM
|
700 |
1 |
|
|a Tang, Dianping
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Chai, Yaqin
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Zhong, Xia
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Liu, Yan
|e verfasserin
|4 aut
|
700 |
1 |
|
|a Dai, Jianyuan
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Langmuir : the ACS journal of surfaces and colloids
|d 1985
|g 20(2004), 17 vom: 17. Aug., Seite 7240-5
|w (DE-627)NLM098181009
|x 1520-5827
|7 nnas
|
773 |
1 |
8 |
|g volume:20
|g year:2004
|g number:17
|g day:17
|g month:08
|g pages:7240-5
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_22
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_721
|
951 |
|
|
|a AR
|
952 |
|
|
|d 20
|j 2004
|e 17
|b 17
|c 08
|h 7240-5
|