X-ray triple refraction and triple absorption in a cobalt-complex crystal

X-ray triple refraction and triple absorption have been quantitatively measured for the first time. The samples were (100)-, (010)- and (001)-oriented plates of a cobalt-complex monoclinic crystal. The apparatus used was an energy-tunable X-ray polarimeter with a phase retarder. The X-ray energy was...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1998. - 5(1998), Pt 3 vom: 01. Mai, Seite 1055-7
1. Verfasser: Okitsu, K (VerfasserIn)
Weitere Verfasser: Ueji, Y, Oguchi, T, Hasegawa, Y, Ohashi, Y, Amemiya, Y
Format: Aufsatz
Sprache:English
Veröffentlicht: 1998
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
Beschreibung
Zusammenfassung:X-ray triple refraction and triple absorption have been quantitatively measured for the first time. The samples were (100)-, (010)- and (001)-oriented plates of a cobalt-complex monoclinic crystal. The apparatus used was an energy-tunable X-ray polarimeter with a phase retarder. The X-ray energy was scanned over a range of 150 eV near the cobalt K-absorption edge. Both the spectra of ellipticity and rotation of polarization were completely different for each crystal plate, which revealed that the biaxial crystal had three refractive indices and three absorption coefficients in the X-ray region. The Kramers-Kronig relation between the real and imaginary parts of the dielectric anisotropy has been quantitatively confirmed for all three different orientations
Beschreibung:Date Completed 02.10.2012
Date Revised 20.07.2004
published: Print-Electronic
Citation Status PubMed-not-MEDLINE
ISSN:0909-0495