An eight-position capillary sample spinning stage for the diffractometer at BL20B at the Photon Factory

An eight-position capillary sample spinning stage has been developed for use in conjunction with the versatile vacuum diffractometer (BIGDIFF) at BL20B at the Photon Factory. BIGDIFF is often used in its powder diffraction mode using powders mounted in capillaries and up to eight imaging plates to r...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 5(1998), Pt 3 vom: 01. Mai, Seite 823-5
1. Verfasser: Creagh, D C (VerfasserIn)
Weitere Verfasser: Foran, G J, Cookson, D J, Garrett, R F, Johnson, F
Format: Aufsatz
Sprache:English
Veröffentlicht: 1998
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM149470843
003 DE-627
005 20231223051806.0
007 tu
008 231223s1998 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0498.xml 
035 |a (DE-627)NLM149470843 
035 |a (NLM)15263665 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Creagh, D C  |e verfasserin  |4 aut 
245 1 3 |a An eight-position capillary sample spinning stage for the diffractometer at BL20B at the Photon Factory 
264 1 |c 1998 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 20.07.2004 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a An eight-position capillary sample spinning stage has been developed for use in conjunction with the versatile vacuum diffractometer (BIGDIFF) at BL20B at the Photon Factory. BIGDIFF is often used in its powder diffraction mode using powders mounted in capillaries and up to eight imaging plates to record the diffraction pattern from the sample. Using the multiple spinning stage a number of diffraction patterns can be recorded on the imaging plates if the imaging-plate cassette is moved behind the Weissenberg screen to a new position after exposure of the sample to the beam. Not only is this system more efficient in terms of time saved in the pumping-down process, but also it has the advantage of allowing the diffraction patterns of standards to be recorded, thereby calibrating both the angle scale of the diffractometer and the intensity scales of the imaging plates absolutely 
650 4 |a Journal Article 
700 1 |a Foran, G J  |e verfasserin  |4 aut 
700 1 |a Cookson, D J  |e verfasserin  |4 aut 
700 1 |a Garrett, R F  |e verfasserin  |4 aut 
700 1 |a Johnson, F  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 5(1998), Pt 3 vom: 01. Mai, Seite 823-5  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:5  |g year:1998  |g number:Pt 3  |g day:01  |g month:05  |g pages:823-5 