Nanosecond-resolved XMCD on ID24 at the ESRF to investigate the element-selective dynamics of magnetization switching of Gd-Co amorphous thin film

The one-bunch filling mode of the ESRF is combined with a microcoil to generate a pulsed-magnetic-field pump phased with respect to the probe that is given by the bunch of photons emitted each turn (357 kHz). Nanosecond-resolved X-ray magnetic circular dichroism (XMCD) is carried out. Besides the mi...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 5(1998), Pt 3 vom: 01. Mai, Seite 750-2
1. Verfasser: Bonfim, M (VerfasserIn)
Weitere Verfasser: Mackay, K, Pizzini, S, San Miguel, A, Tolentino, H, Giles, C, Neisius, T, Hagelstein, M, Baudelet, F, Malgrange, C, Fontaine, A
Format: Aufsatz
Sprache:English
Veröffentlicht: 1998
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM149470606
003 DE-627
005 20231223051806.0
007 tu
008 231223s1998 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0498.xml 
035 |a (DE-627)NLM149470606 
035 |a (NLM)15263641 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Bonfim, M  |e verfasserin  |4 aut 
245 1 0 |a Nanosecond-resolved XMCD on ID24 at the ESRF to investigate the element-selective dynamics of magnetization switching of Gd-Co amorphous thin film 
264 1 |c 1998 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 20.07.2004 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a The one-bunch filling mode of the ESRF is combined with a microcoil to generate a pulsed-magnetic-field pump phased with respect to the probe that is given by the bunch of photons emitted each turn (357 kHz). Nanosecond-resolved X-ray magnetic circular dichroism (XMCD) is carried out. Besides the microcoil, the two other key-elements are the energy-dispersive XAS spectrometer, which yields parallel data acquisition, and the diamond-based quarter-wave plate, which tunes the helicity of the photon alternatively left and right 
650 4 |a Journal Article 
700 1 |a Mackay, K  |e verfasserin  |4 aut 
700 1 |a Pizzini, S  |e verfasserin  |4 aut 
700 1 |a San Miguel, A  |e verfasserin  |4 aut 
700 1 |a Tolentino, H  |e verfasserin  |4 aut 
700 1 |a Giles, C  |e verfasserin  |4 aut 
700 1 |a Neisius, T  |e verfasserin  |4 aut 
700 1 |a Hagelstein, M  |e verfasserin  |4 aut 
700 1 |a Baudelet, F  |e verfasserin  |4 aut 
700 1 |a Malgrange, C  |e verfasserin  |4 aut 
700 1 |a Fontaine, A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 5(1998), Pt 3 vom: 01. Mai, Seite 750-2  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:5  |g year:1998  |g number:Pt 3  |g day:01  |g month:05  |g pages:750-2 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 5  |j 1998  |e Pt 3  |b 01  |c 05  |h 750-2