The rotated-inclined double-crystal monochromator (RIDCM) has been adopted to reduce the heat load from third-generation undulator radiation. The position of the exit X-rays from RIDCM has been calculated as a function of X-ray energy on the basis of diffraction theory including refraction effects....
Veröffentlicht in: | Journal of synchrotron radiation. - 1994. - 5(1998), Pt 3 vom: 01. Mai, Seite 679-81 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
1998
|
Zugriff auf das übergeordnete Werk: | Journal of synchrotron radiation |
Schlagworte: | Journal Article |
Zusammenfassung: | The rotated-inclined double-crystal monochromator (RIDCM) has been adopted to reduce the heat load from third-generation undulator radiation. The position of the exit X-rays from RIDCM has been calculated as a function of X-ray energy on the basis of diffraction theory including refraction effects. The results show that the positions of the exit X-rays vary over a wide range due to asymmetric reflection. Methods of fixing the exit position in RIDCM are also discussed |
---|---|