Initial results from an in-vacuum undulator in the NSLS X-ray ring

A short-period in-vacuum undulator for the NSLS X-ray Ring has been developed in a collaboration between SPring-8 and the NSLS, and has achieved its project design goals during commissioning studies. The device is called IVUN (in-vacuum undulator) and employs magnet arrays (31 periods, with an 11 mm...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 5(1998), Pt 3 vom: 01. Mai, Seite 417-9
1. Verfasser: Stefan, P M (VerfasserIn)
Weitere Verfasser: Tanabe, T, Krinsky, S, Rakowsky, G, Solomon, L, Kitamura, H
Format: Aufsatz
Sprache:English
Veröffentlicht: 1998
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM149469497
003 DE-627
005 20231223051804.0
007 tu
008 231223s1998 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0498.xml 
035 |a (DE-627)NLM149469497 
035 |a (NLM)15263530 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Stefan, P M  |e verfasserin  |4 aut 
245 1 0 |a Initial results from an in-vacuum undulator in the NSLS X-ray ring 
264 1 |c 1998 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.10.2012 
500 |a Date Revised 20.07.2004 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A short-period in-vacuum undulator for the NSLS X-ray Ring has been developed in a collaboration between SPring-8 and the NSLS, and has achieved its project design goals during commissioning studies. The device is called IVUN (in-vacuum undulator) and employs magnet arrays (31 periods, with an 11 mm period) developed at SPring-8, while the requisite vacuum chamber and mechanical systems were developed at the NSLS. At a magnet gap of 3.3 mm, IVUN produces 4.6 keV radiation in the fundamental, with useful photon fluxes in both the second and third harmonics. The magnet gap is adjustable between 2 and 10 mm. A brief overview of IVUN is presented, together with initial commissioning results: the dependence of electron-beam lifetime and bremsstrahlung on magnet gap, and the output radiation spectrum 
650 4 |a Journal Article 
700 1 |a Tanabe, T  |e verfasserin  |4 aut 
700 1 |a Krinsky, S  |e verfasserin  |4 aut 
700 1 |a Rakowsky, G  |e verfasserin  |4 aut 
700 1 |a Solomon, L  |e verfasserin  |4 aut 
700 1 |a Kitamura, H  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 5(1998), Pt 3 vom: 01. Mai, Seite 417-9  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:5  |g year:1998  |g number:Pt 3  |g day:01  |g month:05  |g pages:417-9 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 5  |j 1998  |e Pt 3  |b 01  |c 05  |h 417-9