In-vacuum figure-8 undulator for hard X-rays with both horizontal and vertical polarization
A figure-8 undulator of the in-vacuum type has been adopted as an insertion device for BL24XU, the Hyogo Beamline at SPring-8, to provide hard X-rays with both horizontal and vertical polarization instead of a tandem undulator consisting of horizontal and vertical undulators. The undulator will be o...
Veröffentlicht in: | Journal of synchrotron radiation. - 1994. - 5(1998), Pt 3 vom: 01. Mai, Seite 412-3 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
1998
|
Zugriff auf das übergeordnete Werk: | Journal of synchrotron radiation |
Schlagworte: | Journal Article |
Zusammenfassung: | A figure-8 undulator of the in-vacuum type has been adopted as an insertion device for BL24XU, the Hyogo Beamline at SPring-8, to provide hard X-rays with both horizontal and vertical polarization instead of a tandem undulator consisting of horizontal and vertical undulators. The undulator will be operated with the gap almost fixed at 11.6 mm to provide the fundamental radiation with horizontal polarization at 9.5 keV and the 1.5th harmonic with vertical polarization at 14 keV |
---|---|
Beschreibung: | Date Completed 02.10.2012 Date Revised 20.07.2004 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
ISSN: | 1600-5775 |