Advanced pond system : performance with high rate ponds of different depths and areas

Many domestic Wastewater Stabilisation Ponds (WSPs) or oxidation ponds in New Zealand require upgrading to reduce pollution of receiving waters. Advanced Pond Systems (APS) consisting of an Advanced Facultative Pond, High Rate Pond, Algae Settling Pond and Maturation Pond may provide a cost effectiv...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 48(2003), 2 vom: 25., Seite 259-67
1. Verfasser: Craggs, R J (VerfasserIn)
Weitere Verfasser: Davies-Colley, R J, Tanner, C C, Sukias, J P
Format: Aufsatz
Sprache:English
Veröffentlicht: 2003
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Evaluation Study Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM142518832
003 DE-627
005 20250205011859.0
007 tu
008 231223s2003 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0475.xml 
035 |a (DE-627)NLM142518832 
035 |a (NLM)14510219 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Craggs, R J  |e verfasserin  |4 aut 
245 1 0 |a Advanced pond system  |b performance with high rate ponds of different depths and areas 
264 1 |c 2003 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 25.11.2003 
500 |a Date Revised 10.12.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Many domestic Wastewater Stabilisation Ponds (WSPs) or oxidation ponds in New Zealand require upgrading to reduce pollution of receiving waters. Advanced Pond Systems (APS) consisting of an Advanced Facultative Pond, High Rate Pond, Algae Settling Pond and Maturation Pond may provide a cost effective upgrade option. This paper presents the results of a 2-year study of the performance of two pilot APS systems with High Rate Ponds of different depths and areas. The HRPs of the APS systems both had the same flow rate (5 m3 d(-1)), volume (37.5 m3) and thus hydraulic retention time (7.5 d). However, the East HRP had an operating depth of 0.30 m and a surface area of 128 m2, and the West HRP had an operating depth of 0.45 m and a surface area of 85 m2. APS system performance was compared in terms of improvement of water quality. For nearly all parameters measured, there was little difference in performance between the two systems suggesting that the system with the smaller area could be used without affecting treatment. Comparison of final effluent with typical effluent of New Zealand WSPs showed that APS effluent was of higher quality and much less variable over time 
650 4 |a Evaluation Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Davies-Colley, R J  |e verfasserin  |4 aut 
700 1 |a Tanner, C C  |e verfasserin  |4 aut 
700 1 |a Sukias, J P  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 48(2003), 2 vom: 25., Seite 259-67  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:48  |g year:2003  |g number:2  |g day:25  |g pages:259-67 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 48  |j 2003  |e 2  |b 25  |h 259-67