|
|
|
|
LEADER |
01000naa a22002652 4500 |
001 |
NLM12587751X |
003 |
DE-627 |
005 |
20231222210653.0 |
007 |
tu |
008 |
231222s2003 xx ||||| 00| ||eng c |
028 |
5 |
2 |
|a pubmed24n0420.xml
|
035 |
|
|
|a (DE-627)NLM12587751X
|
035 |
|
|
|a (NLM)12824928
|
040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
041 |
|
|
|a eng
|
100 |
1 |
|
|a Masaki, Mitsuhiro
|e verfasserin
|4 aut
|
245 |
1 |
0 |
|a Two-dimensional visible synchrotron light interferometry for transverse beam-profile measurement at the SPring-8 storage ring
|
264 |
|
1 |
|c 2003
|
336 |
|
|
|a Text
|b txt
|2 rdacontent
|
337 |
|
|
|a ohne Hilfsmittel zu benutzen
|b n
|2 rdamedia
|
338 |
|
|
|a Band
|b nc
|2 rdacarrier
|
500 |
|
|
|a Date Completed 26.09.2003
|
500 |
|
|
|a Date Revised 05.06.2019
|
500 |
|
|
|a published: Print-Electronic
|
500 |
|
|
|a Citation Status PubMed-not-MEDLINE
|
520 |
|
|
|a A two-dimensional visible synchrotron light interferometer has been developed to measure the transverse profile of an electron beam at the SPring-8 storage ring. The new interferometer enables the simultaneous measurement of beam sizes along the major and minor axes and the beam-tilt angle of an assumed elliptical Gaussian distribution. The principle of the interferometer is explained through basic formulae. To calibrate the point-spread function of the interferometer, a simple error model was assumed for disturbances in the amplitude and phase of the light; these disturbances were presumably caused by optical elements, such as mirrors and lenses. The experimental method to determine the parameters in the error model is shown. To verify the two-dimensional profiling capabilities of the interferometer, an electron beam stored in the SPring-8 storage ring operated at various working points was observed. A beam broadening from 20 to 120 microm in the vertical direction and changes in the beam-tilt angle were clearly observed at working points close to the differential resonance. However, the vertical spatial resolution is limited by the available vertical separation of the apertures of the diffracting mask because of the narrow aperture of the upstream vacuum duct
|
650 |
|
4 |
|a Journal Article
|
700 |
1 |
|
|a Takano, Shiro
|e verfasserin
|4 aut
|
773 |
0 |
8 |
|i Enthalten in
|t Journal of synchrotron radiation
|d 1994
|g 10(2003), Pt 4 vom: 01. Juli, Seite 295-302
|w (DE-627)NLM09824129X
|x 1600-5775
|7 nnns
|
773 |
1 |
8 |
|g volume:10
|g year:2003
|g number:Pt 4
|g day:01
|g month:07
|g pages:295-302
|
912 |
|
|
|a GBV_USEFLAG_A
|
912 |
|
|
|a SYSFLAG_A
|
912 |
|
|
|a GBV_NLM
|
912 |
|
|
|a GBV_ILN_40
|
912 |
|
|
|a GBV_ILN_350
|
912 |
|
|
|a GBV_ILN_2005
|
951 |
|
|
|a AR
|
952 |
|
|
|d 10
|j 2003
|e Pt 4
|b 01
|c 07
|h 295-302
|