A windowless small ionization chamber detector has been developed for monitoring the intensity of the microbeam at the ID18F microprobe end-station of the European Synchrotron Radiation Facility. The small dimensions of the ionization chamber (10 mm along the beam direction and 5 mm perpendicular to...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 10(2003), Pt 2 vom: 01. März, Seite 187-90
1. Verfasser: Kocsis, M (VerfasserIn)
Weitere Verfasser: Somogyi, A
Format: Aufsatz
Sprache:English
Veröffentlicht: 2003
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM123826446
003 DE-627
005 20231222202217.0
007 tu
008 231222s2003 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0413.xml 
035 |a (DE-627)NLM123826446 
035 |a (NLM)12606799 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kocsis, M  |e verfasserin  |4 aut 
245 1 0 |a Miniature ionization chamber detector developed for X-ray microprobe measurements 
264 1 |c 2003 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 24.04.2003 
500 |a Date Revised 05.06.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A windowless small ionization chamber detector has been developed for monitoring the intensity of the microbeam at the ID18F microprobe end-station of the European Synchrotron Radiation Facility. The small dimensions of the ionization chamber (10 mm along the beam direction and 5 mm perpendicular to it) make it possible to place it very close to the sample. A pinhole of diameter 50 microm was used for defining the entrance window of the ionization chamber; thus the small counter can be used as an order-selecting aperture while measuring simultaneously the intensity after the aperture. In the present work the technical characteristics, such as the current-voltage curve, stability and linearity, of the small monitor have been tested 
650 4 |a Journal Article 
700 1 |a Somogyi, A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 10(2003), Pt 2 vom: 01. März, Seite 187-90  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:10  |g year:2003  |g number:Pt 2  |g day:01  |g month:03  |g pages:187-90 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 10  |j 2003  |e Pt 2  |b 01  |c 03  |h 187-90