A new extrapolation technique for resolution enhancement of pulse-echo imaging systems

A new, simple extrapolation technique to enhance the lateral resolution of pulse-echo imaging systems is presented. The method attempts to build an image that could be obtained with a transducer aperture larger than that physically available, extrapolating the information contained in the image to b...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1999. - 49(2002), 3 vom: 01. März, Seite 374-82
1. Verfasser: Carotenuto, Riccardo (VerfasserIn)
Weitere Verfasser: Loi, Giovanna, Pappalardo, Massimo
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Comparative Study Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652 4500
001 NLM12132270X
003 DE-627
005 20250203123951.0
007 tu
008 231222s2002 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0405.xml 
035 |a (DE-627)NLM12132270X 
035 |a (NLM)12322888 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Carotenuto, Riccardo  |e verfasserin  |4 aut 
245 1 2 |a A new extrapolation technique for resolution enhancement of pulse-echo imaging systems 
264 1 |c 2002 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 06.11.2002 
500 |a Date Revised 16.09.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a A new, simple extrapolation technique to enhance the lateral resolution of pulse-echo imaging systems is presented. The method attempts to build an image that could be obtained with a transducer aperture larger than that physically available, extrapolating the information contained in the image to be enhanced. The extrapolation process requires small hardware modifications of the standard echographic systems. The computational cost is very low compared with Fourier-based deconvolution approaches. The obtained computer simulations give very interesting and promising r 
650 4 |a Comparative Study 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Loi, Giovanna  |e verfasserin  |4 aut 
700 1 |a Pappalardo, Massimo  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1999  |g 49(2002), 3 vom: 01. März, Seite 374-82  |w (DE-627)NLM098181017  |x 0885-3010  |7 nnns 
773 1 8 |g volume:49  |g year:2002  |g number:3  |g day:01  |g month:03  |g pages:374-82 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 49  |j 2002  |e 3  |b 01  |c 03  |h 374-82