Cryogenically cooled bent double-Laue monochromator for high-energy undulator X-rays (50-200 keV)

A liquid-nitrogen-cooled monochromator for high-energy X-rays consisting of two bent Si(111) Laue crystals adjusted to sequential Rowland conditions has been in operation for over two years at the SRI-CAT sector 1 undulator beamline of the Advanced Photon Source (APS). It delivers over ten times mor...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 9(2002), Pt 5 vom: 01. Sept., Seite 317-22
1. Verfasser: Shastri, S D (VerfasserIn)
Weitere Verfasser: Fezzaa, K, Mashayekhi, A, Lee, W K, Fernandez, P B, Lee, P L
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM120598876
003 DE-627
005 20231222191232.0
007 tu
008 231222s2002 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0402.xml 
035 |a (DE-627)NLM120598876 
035 |a (NLM)12200577 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Shastri, S D  |e verfasserin  |4 aut 
245 1 0 |a Cryogenically cooled bent double-Laue monochromator for high-energy undulator X-rays (50-200 keV) 
264 1 |c 2002 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 09.12.2002 
500 |a Date Revised 05.06.2019 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A liquid-nitrogen-cooled monochromator for high-energy X-rays consisting of two bent Si(111) Laue crystals adjusted to sequential Rowland conditions has been in operation for over two years at the SRI-CAT sector 1 undulator beamline of the Advanced Photon Source (APS). It delivers over ten times more flux than a flat-crystal monochromator does at high energies, without any increase in energy width (DeltaE/E approximately 10(-3)). Cryogenic cooling permits optimal flux, avoiding a sacrifice from the often employed alternative technique of filtration - a technique less effective at sources like the 7 GeV APS, where considerable heat loads can be deposited by high-energy photons, especially at closed undulator gaps. The fixed-offset geometry provides a fully tunable in-line monochromatic beam. In addition to presenting the optics performance, unique crystal design and stable bending mechanism for a cryogenically cooled crystal under high heat load, the bending radii adjustment procedures are described 
650 4 |a Journal Article 
700 1 |a Fezzaa, K  |e verfasserin  |4 aut 
700 1 |a Mashayekhi, A  |e verfasserin  |4 aut 
700 1 |a Lee, W K  |e verfasserin  |4 aut 
700 1 |a Fernandez, P B  |e verfasserin  |4 aut 
700 1 |a Lee, P L  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 9(2002), Pt 5 vom: 01. Sept., Seite 317-22  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:9  |g year:2002  |g number:Pt 5  |g day:01  |g month:09  |g pages:317-22 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 9  |j 2002  |e Pt 5  |b 01  |c 09  |h 317-22