Treatment of anaerobically treated domestic wastewater using rotating biological contactor
A small-scale pilot plant consisting of a three-stage RBC has been investigated for the removal of E. coli, COD fractions and ammonia from the effluent of an UASB reactor treating domestic wastewater. The results obtained reveal that a three-stage system operated at a HRT of 3.0 h represents an effe...
Veröffentlicht in: | Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 45(2002), 10 vom: 01., Seite 371-6 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
2002
|
Zugriff auf das übergeordnete Werk: | Water science and technology : a journal of the International Association on Water Pollution Research |
Schlagworte: | Journal Article Research Support, Non-U.S. Gov't Sewage Ammonia 7664-41-7 Oxygen S88TT14065 |