In vivo droplet vaporization for occlusion therapy and phase aberration correction

The objective was to determine whether a transpulmonary droplet emulsion (90%, <6 microm diameter) could be used to form large gas bubbles (>30 microm) temporarily in vivo. Such bubbles could occlude a targeted capillary bed when used in a large number density. Alternatively, for a very sparse...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control. - 1986. - 49(2002), 6 vom: 25. Juni, Seite 726-38
1. Verfasser: Kripfgans, Oliver D (VerfasserIn)
Weitere Verfasser: Fowlkes, J Brian, Woydt, Michael, Eldevik, Odd P, Carson, Paul L
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:IEEE transactions on ultrasonics, ferroelectrics, and frequency control
Schlagworte:Journal Article Research Support, U.S. Gov't, Non-P.H.S. Research Support, U.S. Gov't, P.H.S. Albumins Contrast Media Emulsions Fluorocarbons
LEADER 01000naa a22002652 4500
001 NLM119485923
003 DE-627
005 20231222184847.0
007 tu
008 231222s2002 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0399.xml 
035 |a (DE-627)NLM119485923 
035 |a (NLM)12075966 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kripfgans, Oliver D  |e verfasserin  |4 aut 
245 1 0 |a In vivo droplet vaporization for occlusion therapy and phase aberration correction 
264 1 |c 2002 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 09.08.2002 
500 |a Date Revised 16.09.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a The objective was to determine whether a transpulmonary droplet emulsion (90%, <6 microm diameter) could be used to form large gas bubbles (>30 microm) temporarily in vivo. Such bubbles could occlude a targeted capillary bed when used in a large number density. Alternatively, for a very sparse population of droplets, the resulting gas bubbles could serve as point beacons for phase aberration corrections in ultrasonic imaging. Gas bubbles can be made in vivo by acoustic droplet vaporization (ADV) of injected, superheated, dodecafluoropentane droplets. Droplets vaporize in an acoustic field whose peak rarefactional pressure exceeds a well-defined threshold. In this new work, it has been found that intraarterial and intravenous injections can be used to introduce the emulsion into the blood stream for subsequent ADV (B- and M-mode on a clinical scanner) in situ. Intravenous administration results in a lower gas bubble yield, possibly because of filtering in the lung, dilution in the blood volume, or other circulatory effects. Results show that for occlusion purposes, a reduction in regional blood flow of 34% can be achieved. Individual point beacons with a +24 dB backscatter amplitude relative to white matter were created by intravenous injection and ADV 
650 4 |a Journal Article 
650 4 |a Research Support, U.S. Gov't, Non-P.H.S. 
650 4 |a Research Support, U.S. Gov't, P.H.S. 
650 7 |a Albumins  |2 NLM 
650 7 |a Contrast Media  |2 NLM 
650 7 |a Emulsions  |2 NLM 
650 7 |a Fluorocarbons  |2 NLM 
700 1 |a Fowlkes, J Brian  |e verfasserin  |4 aut 
700 1 |a Woydt, Michael  |e verfasserin  |4 aut 
700 1 |a Eldevik, Odd P  |e verfasserin  |4 aut 
700 1 |a Carson, Paul L  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t IEEE transactions on ultrasonics, ferroelectrics, and frequency control  |d 1986  |g 49(2002), 6 vom: 25. Juni, Seite 726-38  |w (DE-627)NLM098181017  |x 1525-8955  |7 nnns 
773 1 8 |g volume:49  |g year:2002  |g number:6  |g day:25  |g month:06  |g pages:726-38 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_22 
912 |a GBV_ILN_24 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 49  |j 2002  |e 6  |b 25  |c 06  |h 726-38