Evaluation of an automated, homogeneous enzyme immunoassay for serum thyroxine measurement in dog and cat serum

A homogenous enzyme immunoassay (EIA) for measurement of serum thyroxine (T4) concentration was evaluated for use with canine and feline serum. The EIA method was linear from 0 to 150 nmol T4/L for human serum, 0 to 94 nmol T4/L for feline serum and 10 to 60 nmol T4/L for canine serum. Intra- and in...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Veterinary clinical pathology. - 1975. - 28(1999), 1 vom: 21., Seite 20-28
1. Verfasser: Horney, Barbara S. (VerfasserIn)
Weitere Verfasser: MacKenzie, Allan L., Burton, Shelley A., Olexson, Dennis W., Mitton, Katherine L., Coty, William A., Rinne, Sherrie G.
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 1999
Zugriff auf das übergeordnete Werk:Veterinary clinical pathology
Schlagworte:Journal Article
LEADER 01000naa a22002652 4500
001 NLM119481588
003 DE-627
005 20231222184841.0
007 cr uuu---uuuuu
008 231222s1999 xx |||||o 00| ||eng c
028 5 2 |a pubmed24n0399.xml 
035 |a (DE-627)NLM119481588 
035 |a (NLM)12075533 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Horney, Barbara S.  |e verfasserin  |4 aut 
245 1 0 |a Evaluation of an automated, homogeneous enzyme immunoassay for serum thyroxine measurement in dog and cat serum 
264 1 |c 1999 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 20.11.2019 
500 |a published: Print 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a A homogenous enzyme immunoassay (EIA) for measurement of serum thyroxine (T4) concentration was evaluated for use with canine and feline serum. The EIA method was linear from 0 to 150 nmol T4/L for human serum, 0 to 94 nmol T4/L for feline serum and 10 to 60 nmol T4/L for canine serum. Intra- and interassay precision studies yielded coefficients of variation </= 8% using single point measurements. Method comparison studies gave close agreement between radioimmunoassay (RIA) and EIA results. Correlation coefficients (r values) were 0.88 and 0.97 for canine and feline samples respectively, after application of species-specific factors to correct the calibrator values assigned for human serum samples. The EIA showed no interference from hemolysis at hemoglobin concentrations </= 20 g/L or from moderate lipemia. Highly lipemic specimens could be tested after centrifugation to clarify the sample. The EIA showed less interference from autoantibodies to T4 than the RIA method. The EIA method allows automation of T4 testing in a veterinary hospital or laboratory, and can be integrated with the routine clinical chemistry panel 
650 4 |a Journal Article 
700 1 |a MacKenzie, Allan L.  |e verfasserin  |4 aut 
700 1 |a Burton, Shelley A.  |e verfasserin  |4 aut 
700 1 |a Olexson, Dennis W.  |e verfasserin  |4 aut 
700 1 |a Mitton, Katherine L.  |e verfasserin  |4 aut 
700 1 |a Coty, William A.  |e verfasserin  |4 aut 
700 1 |a Rinne, Sherrie G.  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Veterinary clinical pathology  |d 1975  |g 28(1999), 1 vom: 21., Seite 20-28  |w (DE-627)NLM098159984  |x 1939-165X  |7 nnns 
773 1 8 |g volume:28  |g year:1999  |g number:1  |g day:21  |g pages:20-28 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 28  |j 1999  |e 1  |b 21  |h 20-28