Treatment of waste incinerator air-pollution-control residues with FeSO4 : laboratory investigation of design parameters

The key design parameters of a new process for treatment of air-pollution-control (APC) residues (the Ferrox-process) were investigated in the laboratory. The optimisation involved two different APC-residues from actual incinerator plants. The design parameters considered were: amount of iron oxide...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Waste management & research : the journal of the International Solid Wastes and Public Cleansing Association, ISWA. - 1991. - 20(2002), 1 vom: 04. Feb., Seite 80-9
1. Verfasser: Jensen, D L (VerfasserIn)
Weitere Verfasser: Christensen, T H, Lundtorp, K
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:Waste management & research : the journal of the International Solid Wastes and Public Cleansing Association, ISWA
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Ferrous Compounds Metals, Heavy Reactive Oxygen Species ferrous sulfate 39R4TAN1VT