Generation of dynamically configured check lists for intra-operative problems using a set of covering algorithms

We present a prototype of a decision support system for anesthesia that applies set covering theory. The system is designed to generate dynamically configured check-lists for intra-operative problems. These lists have the potential to help anesthesiologists detect and manage problems in a timely man...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Proceedings. AMIA Symposium. - 1998. - (2001) vom: 28., Seite 593-7
1. Verfasser: Sawa, T (VerfasserIn)
Weitere Verfasser: Ohno-Machado, L
Format: Aufsatz
Sprache:English
Veröffentlicht: 2001
Zugriff auf das übergeordnete Werk:Proceedings. AMIA Symposium
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, P.H.S.
LEADER 01000naa a22002652 4500
001 NLM117237132
003 DE-627
005 20231222180100.0
007 tu
008 231222s2001 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0391.xml 
035 |a (DE-627)NLM117237132 
035 |a (NLM)11837218 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sawa, T  |e verfasserin  |4 aut 
245 1 0 |a Generation of dynamically configured check lists for intra-operative problems using a set of covering algorithms 
264 1 |c 2001 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 24.05.2002 
500 |a Date Revised 13.11.2018 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a We present a prototype of a decision support system for anesthesia that applies set covering theory. The system is designed to generate dynamically configured check-lists for intra-operative problems. These lists have the potential to help anesthesiologists detect and manage problems in a timely manner. The items in the lists consist of major complications that should be considered for a particular case. A set covering algorithm that accommodates multiple problem sets was used to implement the prototype. A simulated case and the system behavior are presented. The ultimate goals of a system such as the one presented are to function as an intelligent alarm module for electronic monitors and to facilitate the task of correcting intra-operative problems 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Research Support, U.S. Gov't, P.H.S. 
700 1 |a Ohno-Machado, L  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Proceedings. AMIA Symposium  |d 1998  |g (2001) vom: 28., Seite 593-7  |w (DE-627)NLM098642928  |x 1531-605X  |7 nnns 
773 1 8 |g year:2001  |g day:28  |g pages:593-7 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |j 2001  |b 28  |h 593-7