Bedside vital signs capture for the non-ICU setting--an open source, PC-based solution

The efficient and reliable capture of vital signs and other bedside data in the non-ICU setting has been a challenging problem for the medical informatics community. The problem is compounded by the complexities associated with storage of this data into an electronic medical record system (EMRS). Th...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Proceedings. AMIA Symposium. - 1998. - (2001) vom: 11., Seite 344-8
1. Verfasser: Kroth, P J (VerfasserIn)
Weitere Verfasser: Belsito, A, Overhage, J M, McDonald, C J
Format: Aufsatz
Sprache:English
Veröffentlicht: 2001
Zugriff auf das übergeordnete Werk:Proceedings. AMIA Symposium
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM11712317X
003 DE-627
005 20250203022409.0
007 tu
008 231222s2001 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0391.xml 
035 |a (DE-627)NLM11712317X 
035 |a (NLM)11825208 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Kroth, P J  |e verfasserin  |4 aut 
245 1 0 |a Bedside vital signs capture for the non-ICU setting--an open source, PC-based solution 
264 1 |c 2001 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 24.05.2002 
500 |a Date Revised 13.11.2018 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a The efficient and reliable capture of vital signs and other bedside data in the non-ICU setting has been a challenging problem for the medical informatics community. The problem is compounded by the complexities associated with storage of this data into an electronic medical record system (EMRS). There are a lack of off-the-shelf solutions that satisfy the basic system requirements of bedside data capture, user authentication, data validation prior to storage, error handling, and convenience. With the current state of technology available, we feel the solution to this problem requires the presence of a PC with custom interface software at the bedside. This allows for the successful interface between available vital signs capture devices, existing EMRS s, and the user. This report summarizes the alternatives we found and our proposed solution to this important problem 
650 4 |a Journal Article 
700 1 |a Belsito, A  |e verfasserin  |4 aut 
700 1 |a Overhage, J M  |e verfasserin  |4 aut 
700 1 |a McDonald, C J  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Proceedings. AMIA Symposium  |d 1998  |g (2001) vom: 11., Seite 344-8  |w (DE-627)NLM098642928  |x 1531-605X  |7 nnns 
773 1 8 |g year:2001  |g day:11  |g pages:344-8 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |j 2001  |b 11  |h 344-8