Nylon membrane-immobilized PCR for detection of bovine viruses

Bridge Technology is an amplification technique in which pairs of primers are immobilized on a solid support, allowing amplification only at the location of the primer pair spot. The technique has diagnostic potential since an array of primer pairs, each specific for a different pathogen, can be use...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:BioTechniques. - 1993. - 32(2002), 1 vom: 15. Jan., Seite 74-6, 78, 80
1. Verfasser: Onodera, Kenji (VerfasserIn)
Weitere Verfasser: d'Offay, Jean, Melcher, Ulrich
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:BioTechniques
Schlagworte:Research Support, Non-U.S. Gov't Technical Report Journal Article DNA Primers DNA, Complementary DNA, Viral Membranes, Artificial Nylons
LEADER 01000caa a22002652 4500
001 NLM116968265
003 DE-627
005 20250203015557.0
007 tu
008 231222s2002 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0390.xml 
035 |a (DE-627)NLM116968265 
035 |a (NLM)11808702 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Onodera, Kenji  |e verfasserin  |4 aut 
245 1 0 |a Nylon membrane-immobilized PCR for detection of bovine viruses 
264 1 |c 2002 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 25.06.2002 
500 |a Date Revised 28.09.2018 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a Bridge Technology is an amplification technique in which pairs of primers are immobilized on a solid support, allowing amplification only at the location of the primer pair spot. The technique has diagnostic potential since an array of primer pairs, each specific for a different pathogen, can be used with a diagnostic sample without inter-pair interactions that plague the development of multiplex PCRs. As a result, one assay should be able to determine which of multiple pathogens are present and which are absent in each sample. As test material, we examined the specificity of detection of the RNA-containing bovine viral diarrhea virus (BVDV) and two DNA-containing bovine herpesviruses 1 and 2 (BHV-1 and BHV-2). Nylon membranes with two spots of UV-immobilized primer pairs--one for BVDV and one for BHV--were used in amplification with both corresponding templates, with each template singly and with no template. When amplification was assayed by chemiluminescent detection of incorporated DIG-nucleotides, the expected amplification patterns were obtained 
650 4 |a Research Support, Non-U.S. Gov't 
650 4 |a Technical Report 
650 4 |a Journal Article 
650 7 |a DNA Primers  |2 NLM 
650 7 |a DNA, Complementary  |2 NLM 
650 7 |a DNA, Viral  |2 NLM 
650 7 |a Membranes, Artificial  |2 NLM 
650 7 |a Nylons  |2 NLM 
700 1 |a d'Offay, Jean  |e verfasserin  |4 aut 
700 1 |a Melcher, Ulrich  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t BioTechniques  |d 1993  |g 32(2002), 1 vom: 15. Jan., Seite 74-6, 78, 80  |w (DE-627)NLM012627046  |x 0736-6205  |7 nnns 
773 1 8 |g volume:32  |g year:2002  |g number:1  |g day:15  |g month:01  |g pages:74-6, 78, 80 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_21 
912 |a GBV_ILN_22 
912 |a GBV_ILN_39 
912 |a GBV_ILN_40 
912 |a GBV_ILN_50 
912 |a GBV_ILN_60 
912 |a GBV_ILN_62 
912 |a GBV_ILN_65 
912 |a GBV_ILN_70 
912 |a GBV_ILN_99 
912 |a GBV_ILN_121 
912 |a GBV_ILN_130 
912 |a GBV_ILN_227 
912 |a GBV_ILN_350 
912 |a GBV_ILN_618 
912 |a GBV_ILN_640 
912 |a GBV_ILN_754 
912 |a GBV_ILN_2001 
912 |a GBV_ILN_2002 
912 |a GBV_ILN_2003 
912 |a GBV_ILN_2005 
912 |a GBV_ILN_2006 
912 |a GBV_ILN_2007 
912 |a GBV_ILN_2008 
912 |a GBV_ILN_2009 
912 |a GBV_ILN_2010 
912 |a GBV_ILN_2012 
912 |a GBV_ILN_2015 
912 |a GBV_ILN_2018 
912 |a GBV_ILN_2023 
912 |a GBV_ILN_2035 
912 |a GBV_ILN_2040 
912 |a GBV_ILN_2060 
912 |a GBV_ILN_2099 
912 |a GBV_ILN_2105 
912 |a GBV_ILN_2121 
912 |a GBV_ILN_2470 
951 |a AR 
952 |d 32  |j 2002  |e 1  |b 15  |c 01  |h 74-6, 78, 80