Characterization of iron and manganese precipitates from an in situ ground water treatment plant

Aquifer samples from the precipitation zone of an in situ iron and manganese removal plant that was operated for 10 years were analyzed for iron and manganese minerals. Measurements were performed by various chemical extraction techniques (5 M HCI, 0.008 M Ti(III)-EDTA, 0.114 M ascorbic acid), X-ray...

Description complète

Détails bibliographiques
Publié dans:Ground water. - 1979. - 39(2001), 6 vom: 31. Nov., Seite 921-30
Auteur principal: Mettler, S (Auteur)
Autres auteurs: Abdelmoula, M, Hoehn, E, Schoenenberger, R, Weidler, P, von Gunten, U
Format: Article
Langue:English
Publié: 2001
Accès à la collection:Ground water
Sujets:Journal Article Research Support, Non-U.S. Gov't Soil Manganese 42Z2K6ZL8P Iron E1UOL152H7
Description
Résumé:Aquifer samples from the precipitation zone of an in situ iron and manganese removal plant that was operated for 10 years were analyzed for iron and manganese minerals. Measurements were performed by various chemical extraction techniques (5 M HCI, 0.008 M Ti(III)-EDTA, 0.114 M ascorbic acid), X-ray diffraction and Mössbauer spectroscopy. Chemical extractions showed that iron was precipitated as ferric oxides, whereas manganese was not oxidized but deposited as Mn(II) probably within carbonates. The ferric oxides in particular accumulate preferentially in the smaller grain- size fractions. This tendency was observed to a lesser extent for manganese. X-ray diffraction and Mössbauer spectroscopy showed that the ferric oxides were mainly crystalline (goethite, 50% to 100% of the iron). Ferrihydrite was found as well, but only as a minor fraction (< or = 12%). Pure manganese minerals were not found by X-ray diffraction. The precipitated amounts of iron (5 to 27 micromol/g Fe as ferric oxide) and manganese (1 to 4 micromol/g Mn) during 10 years operation of the treatment plant agree with values that were estimated from operational parameters (9 to 31 micromol/g Fe and 3 to 6 micromol/g Mn). Considering the small amounts of precipitated iron and manganese, no long-term risks of clogging of the aquifer are expected
Description:Date Completed 20.02.2002
Date Revised 05.11.2019
published: Print
Citation Status MEDLINE
ISSN:1745-6584