EXAFS (extended X-ray absorption fine structure) experiments were performed at several different temperatures for a series of 3d transition metal ions (Cr3+, Fe3+, Fe2+, Ni2+, Co2+, Zn2+) in aqueous solutions. Anharmonic EXAFS analyses, which include up to third order cumulant, were carried out to s...
Veröffentlicht in: | Journal of synchrotron radiation. - 1994. - 8(2001), Pt 2 vom: 01. März, Seite 680-2 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
2001
|
Zugriff auf das übergeordnete Werk: | Journal of synchrotron radiation |
Schlagworte: | Journal Article |
Zusammenfassung: | EXAFS (extended X-ray absorption fine structure) experiments were performed at several different temperatures for a series of 3d transition metal ions (Cr3+, Fe3+, Fe2+, Ni2+, Co2+, Zn2+) in aqueous solutions. Anharmonic EXAFS analyses, which include up to third order cumulant, were carried out to study on the metal-oxygen bonding potential. According to the model in which the dissociation process is dominant for the ligand-water exchange reaction, the dissociation energy has been first evaluated from EXAFS in solution phase |
---|---|
Beschreibung: | Date Completed 06.09.2001 Date Revised 05.06.2019 published: Print Citation Status PubMed-not-MEDLINE |