Data-based modelling and proportional-integral-plus (pip) control of nitrate in an activated sludge benchmark

This paper presents the result of an investigation into the Proportional Integral Plus (PIP) control of nitrate in the second zone of an activated sludge benchmark. A data-based reduced order model is used as the control model and identified using the Simplified Refined Instrumental Variable (SRIV)...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 44(2001), 1 vom: 15., Seite 87-94
1. Verfasser: Ghavipanjeh, F (VerfasserIn)
Weitere Verfasser: Taylor, C J, Young, P C, Chotai, A
Format: Aufsatz
Sprache:English
Veröffentlicht: 2001
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Nitrates Sewage
LEADER 01000caa a22002652 4500
001 NLM113960204
003 DE-627
005 20250202184823.0
007 tu
008 231222s2001 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0380.xml 
035 |a (DE-627)NLM113960204 
035 |a (NLM)11496682 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Ghavipanjeh, F  |e verfasserin  |4 aut 
245 1 0 |a Data-based modelling and proportional-integral-plus (pip) control of nitrate in an activated sludge benchmark 
264 1 |c 2001 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 07.12.2001 
500 |a Date Revised 15.11.2006 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a This paper presents the result of an investigation into the Proportional Integral Plus (PIP) control of nitrate in the second zone of an activated sludge benchmark. A data-based reduced order model is used as the control model and identified using the Simplified Refined Instrumental Variable (SRIV) identification and estimation algorithm. The PIP control design is based on the Non Minimum State Space (NMSS) form and State Variable Feedback (SVF) methodology. The PIP controller is tested against dynamic load disturbances and compared with the response of a well tuned PI controller 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Nitrates  |2 NLM 
650 7 |a Sewage  |2 NLM 
700 1 |a Taylor, C J  |e verfasserin  |4 aut 
700 1 |a Young, P C  |e verfasserin  |4 aut 
700 1 |a Chotai, A  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 44(2001), 1 vom: 15., Seite 87-94  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:44  |g year:2001  |g number:1  |g day:15  |g pages:87-94 