X-ray magnetic circular dichroism imaging with hard X-rays

X-ray polarization-contrast images resulting from X-ray magnetic circular dichroism (XMCD) in the hard X-ray region have been successfully recorded for the first time. The apparatus used consisted of an X-ray polarizer, double X-ray phase retarders, and a high-spatial-resolution X-ray charge-coupled...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 8(2001), 3 vom: 01. Mai, Seite 1021-6
1. Verfasser: Sato, K (VerfasserIn)
Weitere Verfasser: Ueji, Y, Okitsu, K, Matsushita, T, Amemiya, Y
Format: Aufsatz
Sprache:English
Veröffentlicht: 2001
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't
LEADER 01000caa a22002652c 4500
001 NLM113873387
003 DE-627
005 20250202183523.0
007 tu
008 231222s2001 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0380.xml 
035 |a (DE-627)NLM113873387 
035 |a (NLM)11486407 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Sato, K  |e verfasserin  |4 aut 
245 1 0 |a X-ray magnetic circular dichroism imaging with hard X-rays 
264 1 |c 2001 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 23.08.2001 
500 |a Date Revised 05.06.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a X-ray polarization-contrast images resulting from X-ray magnetic circular dichroism (XMCD) in the hard X-ray region have been successfully recorded for the first time. The apparatus used consisted of an X-ray polarizer, double X-ray phase retarders, and a high-spatial-resolution X-ray charge-coupled-device detector. The sample used was a hexagonal-close-packed cobalt polycrystal foil having a thickness of about 4 microns. The X-ray polarization-contrast image resulting from XMCD was observed at a photon energy of 10 eV above the cobalt K-absorption edge (7709 eV). The observed contrast in the image was reversed by inversion of the magnetic field. Furthermore, the contrast was reversed again at a photon energy of 32 eV above the cobalt K-absorption edge 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
700 1 |a Ueji, Y  |e verfasserin  |4 aut 
700 1 |a Okitsu, K  |e verfasserin  |4 aut 
700 1 |a Matsushita, T  |e verfasserin  |4 aut 
700 1 |a Amemiya, Y  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 8(2001), 3 vom: 01. Mai, Seite 1021-6  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnas 
773 1 8 |g volume:8  |g year:2001  |g number:3  |g day:01  |g month:05  |g pages:1021-6 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 8  |j 2001  |e 3  |b 01  |c 05  |h 1021-6