Overview of the tunable beamlines for protein crystallography at the EMBL Hamburg Outstation; an analysis of current and future usage and developments

The EMBL Hamburg Outstation currently operates two tunable protein crystallography beamlines suitable for single and multiple anomalous diffraction (SAD/MAD) experiments. The first beamline, designated X31, is located on a bending magnet of the DORIS III storage ring whereas the second beamline, BW7...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 8(2001), 4 vom: 01. Juli, Seite 1113-20
1. Verfasser: Pohl, E (VerfasserIn)
Weitere Verfasser: González, A, Hermes, C, van Silfhout, R G
Format: Aufsatz
Sprache:English
Veröffentlicht: 2001
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Review Proteins
LEADER 01000naa a22002652 4500
001 NLM113872941
003 DE-627
005 20231222164739.0
007 tu
008 231222s2001 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0380.xml 
035 |a (DE-627)NLM113872941 
035 |a (NLM)11486364 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Pohl, E  |e verfasserin  |4 aut 
245 1 0 |a Overview of the tunable beamlines for protein crystallography at the EMBL Hamburg Outstation; an analysis of current and future usage and developments 
264 1 |c 2001 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 23.08.2001 
500 |a Date Revised 05.06.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a The EMBL Hamburg Outstation currently operates two tunable protein crystallography beamlines suitable for single and multiple anomalous diffraction (SAD/MAD) experiments. The first beamline, designated X31, is located on a bending magnet of the DORIS III storage ring whereas the second beamline, BW7A, is positioned at a multipole wiggler at the same storage ring. X31 is equipped with an energy stabilization device to ensure constant wavelength during longer data-collection periods. The in-house built crystallographic end-station is now equipped with a Mar345 imaging-plate scanner as a detector. The wiggler beamline BW7A features a novel sagitally focusing monochromator. The end-station used here has also been developed and built in-house. The beamline is currently operated with a Mar 165 CCD detector. In this paper the hardware and software developments of the last years will be summarized and the outlook for substantial upgrades will be given. The future plans include the design and construction of a third tunable beamline, designated X12, for protein crystallography. The development of automated beamlines for protein crystallography is of particular importance with respect to structural genomics initiatives. The analysis of the projects of the last years shows the wide range of anomalous scatterer used on the tunable beamlines thus demonstrating the need of a wide range of accessible energies and fast and reliable energy changes 
650 4 |a Journal Article 
650 4 |a Review 
650 7 |a Proteins  |2 NLM 
700 1 |a González, A  |e verfasserin  |4 aut 
700 1 |a Hermes, C  |e verfasserin  |4 aut 
700 1 |a van Silfhout, R G  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 8(2001), 4 vom: 01. Juli, Seite 1113-20  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:8  |g year:2001  |g number:4  |g day:01  |g month:07  |g pages:1113-20 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 8  |j 2001  |e 4  |b 01  |c 07  |h 1113-20