Evaluation of an integrated membrane system for water repurification
An integrated membrane system was evaluated for water repurification. Performance evaluation of the membrane system was based on three criteria: flux and fouling, disinfection capability, and rejection of pollutants. Minimal membrane fouling was observed for all of the membranes employed in the stud...
Veröffentlicht in: | Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 43(2001), 10 vom: 21., Seite 219-24 |
---|---|
1. Verfasser: | |
Weitere Verfasser: | , , |
Format: | Aufsatz |
Sprache: | English |
Veröffentlicht: |
2001
|
Zugriff auf das übergeordnete Werk: | Water science and technology : a journal of the International Association on Water Pollution Research |
Schlagworte: | Journal Article |
Zusammenfassung: | An integrated membrane system was evaluated for water repurification. Performance evaluation of the membrane system was based on three criteria: flux and fouling, disinfection capability, and rejection of pollutants. Minimal membrane fouling was observed for all of the membranes employed in the study. Significant contaminant rejection was also achieved by the membrane system purifying the reclaimed water to meet and exceed drinking water standards. Wide range of virus rejection was observed for the membranes, which was dependent on the membrane type, manufacturer, and the fouling status. Overall, the results of this study demonstrated that the integrated membrane system is a very effective and reliable process for water repurification |
---|---|
Beschreibung: | Date Completed 04.12.2001 Date Revised 04.07.2001 published: Print Citation Status MEDLINE |