BP Refinery (Bulwer Island) Ltd (BP) located on the eastern Australian coast is currently undergoing a major expansion as a part of the Queensland Clean Fuels Project. The associated wastewater treatment plant upgrade will provide a better quality of treated effluent than is currently possible with...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 43(2001), 3 vom: 18., Seite 339-46
1. Verfasser: Hudson, N (VerfasserIn)
Weitere Verfasser: Doyle, J, Lant, P, Roach, N, de Bruyn, B, Staib, C
Format: Aufsatz
Sprache:English
Veröffentlicht: 2001
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Industrial Waste Petroleum Nitrogen N762921K75
LEADER 01000naa a22002652 4500
001 NLM112871518
003 DE-627
005 20231222162653.0
007 tu
008 231222s2001 xx ||||| 00| ||eng c
028 5 2 |a pubmed24n0377.xml 
035 |a (DE-627)NLM112871518 
035 |a (NLM)11381925 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Hudson, N  |e verfasserin  |4 aut 
245 1 0 |a Sequencing batch reactor technology  |b the key to a BP refinery (Bulwer Island) upgraded environmental protection system--a low cost lagoon based retro-fit 
264 1 |c 2001 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 28.06.2001 
500 |a Date Revised 21.11.2013 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a BP Refinery (Bulwer Island) Ltd (BP) located on the eastern Australian coast is currently undergoing a major expansion as a part of the Queensland Clean Fuels Project. The associated wastewater treatment plant upgrade will provide a better quality of treated effluent than is currently possible with the existing infrastructure, and which will be of a sufficiently high standard to meet not only the requirements of imposed environmental legislation but also BP's environmental objectives. A number of challenges were faced when considering the upgrade, particularly; cost constraints and limited plot space, highly variable wastewater, toxicity issues, and limited hydraulic head. Sequencing Batch Reactor (SBR) Technology was chosen for the lagoon upgrade based on the following; SBR technology allowed a retro-fit of the existing earthen lagoon without the need for any additional substantial concrete structures, a dual lagoon system allowed partial treatment of wastewaters during construction, SBRs give substantial process flexibility, SBRs have the ability to easily modify process parameters without any physical modifications, and significant cost benefits. This paper presents the background to this application, an outline of laboratory studies carried out on the wastewater and details the full scale design issues and methods for providing a cost effective, efficient treatment system using the existing lagoon system 
650 4 |a Journal Article 
650 7 |a Industrial Waste  |2 NLM 
650 7 |a Petroleum  |2 NLM 
650 7 |a Nitrogen  |2 NLM 
650 7 |a N762921K75  |2 NLM 
700 1 |a Doyle, J  |e verfasserin  |4 aut 
700 1 |a Lant, P  |e verfasserin  |4 aut 
700 1 |a Roach, N  |e verfasserin  |4 aut 
700 1 |a de Bruyn, B  |e verfasserin  |4 aut 
700 1 |a Staib, C  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 43(2001), 3 vom: 18., Seite 339-46  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:43  |g year:2001  |g number:3  |g day:18  |g pages:339-46 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 43  |j 2001  |e 3  |b 18  |h 339-46