Value of serum PSA and PAP measurement with newly developed latex turbidimetric immunoassay

Serum prostate specific antigen (PSA) and prostatic acid-phosphatase (PAP) levels in normal controls, and patients with prostate cancer, benign prostate hypertrophy (BPH) and other urological diseases were examined with a newly developed latex turbidimetric immunoassay (LPIA ACE PSA, LPIA ACE PAP, I...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Hinyokika kiyo. Acta urologica Japonica. - 1962. - 41(1995), 6 vom: 20. Juni, Seite 439-45
1. Verfasser: Akino, H (VerfasserIn)
Weitere Verfasser: Tsuka, H, Okada, K, Tsuchiya, Y, Matsubara, M, Arimura, K
Format: Aufsatz
Sprache:Japanese
Veröffentlicht: 1995
Zugriff auf das übergeordnete Werk:Hinyokika kiyo. Acta urologica Japonica
Schlagworte:Clinical Trial Comparative Study English Abstract Journal Article Research Support, Non-U.S. Gov't Biomarkers, Tumor Reagent Kits, Diagnostic Acid Phosphatase EC 3.1.3.2 Prostate-Specific Antigen EC 3.4.21.77
Beschreibung
Zusammenfassung:Serum prostate specific antigen (PSA) and prostatic acid-phosphatase (PAP) levels in normal controls, and patients with prostate cancer, benign prostate hypertrophy (BPH) and other urological diseases were examined with a newly developed latex turbidimetric immunoassay (LPIA ACE PSA, LPIA ACE PAP, IATRON LABORATORIES, INC., Tokyo, Japan). The advantageous characteristics of this method are small amount (10 microliters) of serum required and short time (about 20 min.) for performing this assay. There was a high linear correlation between LPIA ACE PSA and MARKIT-F PA (r2 = 0.953), between LPIA ACE PSA and TANDEM-E PSA (r2 = 0.881) and between LPIA ACE PAP and ABBOTT-PAP EIA (r2 = 0.946). When the BPH patients (n = 110) were used as negative controls, the cut-off value of PSA was determined to be 4.3 ng/ml. Using this level as the cut-off value, the sensitivity was 78% (42 positive/54 untreated prostate cancer patients), specificity (negative rate in BPH patients) was 95% and efficiency was 89%. In a follow-up study of prostate cancer, the PSA value was elevated above the cut-off value in 68% at the time of clinical progression. These findings suggest that LPIA ACE PSA is a useful tool for serum PSA measurement. The cut-off value of PAP measured with LPIA ACE PAP was 9.0 ng/ml, which was determined by the same method as PSA. The sensitivity, specificity and efficiency ware 39%, 96% and 77%, respectively. These findings indicate that PAP is less useful than PSA in the diagnosis of prostate cancer.(ABSTRACT TRUNCATED AT 250 WORDS)
Beschreibung:Date Completed 15.09.1995
Date Revised 19.11.2015
published: Print
Citation Status MEDLINE
ISSN:0018-1994