A clinical evaluation of AMS 700 penile prosthesis in the treatment of impotence

The AMS 700TM & 700 CXTM penile prosthesis was implanted in 34 organic and mixed-type impotent patients between November, 1984 and July, 1988. The patients' ages ranged between 32 and 70, with an average age of 57.2. Twelve weeks after implantation, the prosthesis was evaluated in terms of...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Hinyokika kiyo. Acta urologica Japonica. - 1962. - 35(1989), 5 vom: 15. Mai, Seite 913-20
1. Verfasser: Shirai, M (VerfasserIn)
Weitere Verfasser: Takanami, M, Kaneko, S, Fujioka, T, Aoki, H, Okamoto, S, Nukui, F, Fujino, A, Kihara, Y, Nakano, H
Format: Aufsatz
Sprache:Japanese
Veröffentlicht: 1989
Zugriff auf das übergeordnete Werk:Hinyokika kiyo. Acta urologica Japonica
Schlagworte:Clinical Trial Journal Article Multicenter Study
LEADER 01000caa a22002652 4500
001 NLM026602970
003 DE-627
005 20250126021300.0
007 tu
008 231221s1989 xx ||||| 00| ||jpn c
028 5 2 |a pubmed25n0089.xml 
035 |a (DE-627)NLM026602970 
035 |a (NLM)2678969 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a jpn 
100 1 |a Shirai, M  |e verfasserin  |4 aut 
245 1 2 |a A clinical evaluation of AMS 700 penile prosthesis in the treatment of impotence 
264 1 |c 1989 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 02.11.1989 
500 |a Date Revised 10.12.2019 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a The AMS 700TM & 700 CXTM penile prosthesis was implanted in 34 organic and mixed-type impotent patients between November, 1984 and July, 1988. The patients' ages ranged between 32 and 70, with an average age of 57.2. Twelve weeks after implantation, the prosthesis was evaluated in terms of patient satisfaction with sexual intercourse and postoperative complications. Twenty three patients (67.7%) were highly satisfied, 7 (20.3%) satisfied, 3 (8.8%) dissatisfied and 1 patient worsened (2.9%). Severe complication was found in two cases, both of them being complicated by infection; as a result the prosthesis was removed. Utility of the prosthesis, e.g. effectiveness and safety was; high utility in 26 cases (76.5%), moderate utility in 7 cases (20.6%), and no favorable in one case (2.9%). Thus, overall effectiveness and safety of the AMS 700 penile prosthesis, with its excellent cosmetic appearance upon implantation, were demonstrated by the above findings 
650 4 |a Clinical Trial 
650 4 |a Journal Article 
650 4 |a Multicenter Study 
700 1 |a Takanami, M  |e verfasserin  |4 aut 
700 1 |a Kaneko, S  |e verfasserin  |4 aut 
700 1 |a Fujioka, T  |e verfasserin  |4 aut 
700 1 |a Aoki, H  |e verfasserin  |4 aut 
700 1 |a Okamoto, S  |e verfasserin  |4 aut 
700 1 |a Nukui, F  |e verfasserin  |4 aut 
700 1 |a Fujino, A  |e verfasserin  |4 aut 
700 1 |a Kihara, Y  |e verfasserin  |4 aut 
700 1 |a Nakano, H  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Hinyokika kiyo. Acta urologica Japonica  |d 1962  |g 35(1989), 5 vom: 15. Mai, Seite 913-20  |w (DE-627)NLM012631779  |x 0018-1994  |7 nnns 
773 1 8 |g volume:35  |g year:1989  |g number:5  |g day:15  |g month:05  |g pages:913-20 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_20 
912 |a GBV_ILN_22 
912 |a GBV_ILN_40 
912 |a GBV_ILN_60 
912 |a GBV_ILN_72 
912 |a GBV_ILN_120 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2001 
912 |a GBV_ILN_2003 
912 |a GBV_ILN_2005 
912 |a GBV_ILN_2006 
912 |a GBV_ILN_2008 
912 |a GBV_ILN_2010 
912 |a GBV_ILN_2012 
912 |a GBV_ILN_2018 
951 |a AR 
952 |d 35  |j 1989  |e 5  |b 15  |c 05  |h 913-20