A sensitive microplate assay for glycoproteins that utilizes an immunological digoxigenin-based detection system

A sensitive microplate assay for glycoproteins, based on an immunological digoxigenin-based detection system, is described. When log absorbance was plotted against log concentration, linear standard curves were obtained over the range 25 ng/ml to 25 microliters/ml with bovine submaxillary mucin, por...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:BioTechniques. - 1988. - 12(1992), 2 vom: 01. Feb., Seite 160, 162
1. Verfasser: Devine, P L (VerfasserIn)
Format: Aufsatz
Sprache:English
Veröffentlicht: 1992
Zugriff auf das übergeordnete Werk:BioTechniques
Schlagworte:Journal Article Glycoproteins Polysaccharides Reagent Kits, Diagnostic Digoxigenin NQ1SX9LNAU
LEADER 01000caa a22002652 4500
001 NLM015981940
003 DE-627
005 20250124200801.0
007 tu
008 231221s1992 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0054.xml 
035 |a (DE-627)NLM015981940 
035 |a (NLM)1616701 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Devine, P L  |e verfasserin  |4 aut 
245 1 2 |a A sensitive microplate assay for glycoproteins that utilizes an immunological digoxigenin-based detection system 
264 1 |c 1992 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 05.08.1992 
500 |a Date Revised 21.11.2013 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a A sensitive microplate assay for glycoproteins, based on an immunological digoxigenin-based detection system, is described. When log absorbance was plotted against log concentration, linear standard curves were obtained over the range 25 ng/ml to 25 microliters/ml with bovine submaxillary mucin, porcine stomach mucin, fetal calf fetuin, asialofetuin and human transferrin. This detection limit and range are far superior to other assays that have been described. The use of the microtiter plate format means that a large number of samples can be assayed with ease. Due to the broad range of the assay, the concentration of the sample is not a particular problem, and samples above the upper cutoff value can be serially diluted in the microtiter plate to find an appropriate value 
650 4 |a Journal Article 
650 7 |a Glycoproteins  |2 NLM 
650 7 |a Polysaccharides  |2 NLM 
650 7 |a Reagent Kits, Diagnostic  |2 NLM 
650 7 |a Digoxigenin  |2 NLM 
650 7 |a NQ1SX9LNAU  |2 NLM 
773 0 8 |i Enthalten in  |t BioTechniques  |d 1988  |g 12(1992), 2 vom: 01. Feb., Seite 160, 162  |w (DE-627)NLM012627046  |x 0736-6205  |7 nnns 
773 1 8 |g volume:12  |g year:1992  |g number:2  |g day:01  |g month:02  |g pages:160, 162 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_21 
912 |a GBV_ILN_22 
912 |a GBV_ILN_39 
912 |a GBV_ILN_40 
912 |a GBV_ILN_50 
912 |a GBV_ILN_60 
912 |a GBV_ILN_62 
912 |a GBV_ILN_65 
912 |a GBV_ILN_70 
912 |a GBV_ILN_99 
912 |a GBV_ILN_121 
912 |a GBV_ILN_130 
912 |a GBV_ILN_227 
912 |a GBV_ILN_350 
912 |a GBV_ILN_618 
912 |a GBV_ILN_640 
912 |a GBV_ILN_754 
912 |a GBV_ILN_2001 
912 |a GBV_ILN_2002 
912 |a GBV_ILN_2003 
912 |a GBV_ILN_2005 
912 |a GBV_ILN_2006 
912 |a GBV_ILN_2007 
912 |a GBV_ILN_2008 
912 |a GBV_ILN_2009 
912 |a GBV_ILN_2010 
912 |a GBV_ILN_2012 
912 |a GBV_ILN_2015 
912 |a GBV_ILN_2018 
912 |a GBV_ILN_2023 
912 |a GBV_ILN_2035 
912 |a GBV_ILN_2040 
912 |a GBV_ILN_2060 
912 |a GBV_ILN_2099 
912 |a GBV_ILN_2105 
912 |a GBV_ILN_2121 
912 |a GBV_ILN_2470 
951 |a AR 
952 |d 12  |j 1992  |e 2  |b 01  |c 02  |h 160, 162