Development of a New Model for Batch Sedimentation and Application to Secondary Settling Tanks Design

Assuming that settling takes place in two zones (a constant rate zone and a variable rate zone), a model using four parameters accounting for the nature of the water-suspension system has been proposed for describing batch sedimentation processes. The sludge volume index (SVI) has been expressed in...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water Environment Research. - THE WATER ENVIRONMENT FEDERATION. - 77(2005), 7, Seite 3066-3073
1. Verfasser: Karamisheva, Ralica D. (VerfasserIn)
Weitere Verfasser: Islam, M. A.
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:Water Environment Research
Schlagworte:Activated sludge Secondary settling Flux theory Sludge volume index Zone settling velocity Applied sciences Mathematics Physical sciences Economics
LEADER 01000caa a22002652 4500
001 JST088360768
003 DE-627
005 20240623212359.0
007 cr uuu---uuuuu
008 150325s2005 xx |||||o 00| ||eng c
035 |a (DE-627)JST088360768 
035 |a (JST)25045927 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Karamisheva, Ralica D.  |e verfasserin  |4 aut 
245 1 0 |a Development of a New Model for Batch Sedimentation and Application to Secondary Settling Tanks Design 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
520 |a Assuming that settling takes place in two zones (a constant rate zone and a variable rate zone), a model using four parameters accounting for the nature of the water-suspension system has been proposed for describing batch sedimentation processes. The sludge volume index (SVI) has been expressed in terms of these parameters. Some disadvantages of the SVI application as a design parameter have been pointed out, and it has been shown that a relationship between zone settling velocity and sludge concentration is more consistent for describing the settling behavior and for design of settling tanks. The permissible overflow rate has been related to the technological parameters of secondary settling tank by simple working equations. The graphical representations of these equations could be used to optimize the design and operation of secondary settling tanks. 
540 |a Copyright 2005 The Water Environment Federation (WEF) 
650 4 |a Activated sludge 
650 4 |a Secondary settling 
650 4 |a Flux theory 
650 4 |a Sludge volume index 
650 4 |a Zone settling velocity 
650 4 |a Applied sciences  |x Materials science  |x Materials  |x Waste materials  |x Sludge  |x Activated sludge 
650 4 |a Mathematics  |x Mathematical values  |x Mathematical constants 
650 4 |a Mathematics  |x Applied mathematics  |x Statistics  |x Applied statistics  |x Statistical models  |x Parametric models 
650 4 |a Applied sciences  |x Research methods  |x Modeling 
650 4 |a Applied sciences  |x Materials science  |x Materials  |x Waste materials  |x Sludge 
650 4 |a Applied sciences  |x Engineering  |x Civil engineering  |x Sanitary engineering  |x Environmental engineering  |x Waste management  |x Waste treatment  |x Wastewater treatment 
650 4 |a Physical sciences  |x Chemistry  |x Chemical mixtures  |x Suspended solids 
650 4 |a Mathematics  |x Mathematical expressions 
650 4 |a Mathematics  |x Mathematical procedures 
650 4 |a Economics  |x Economic disciplines  |x Financial economics  |x Finance  |x Interest  |x Interest rates  |x Variable interest rates  |x Research Papers 
655 4 |a research-article 
700 1 |a Islam, M. A.  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water Environment Research  |d THE WATER ENVIRONMENT FEDERATION  |g 77(2005), 7, Seite 3066-3073  |w (DE-627)592375684  |w (DE-600)2051010-X  |x 15547531  |7 nnns 
773 1 8 |g volume:77  |g year:2005  |g number:7  |g pages:3066-3073 
856 4 0 |u https://www.jstor.org/stable/25045927  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_JST 
912 |a GBV_ILN_11 
912 |a GBV_ILN_20 
912 |a GBV_ILN_22 
912 |a GBV_ILN_23 
912 |a GBV_ILN_24 
912 |a GBV_ILN_31 
912 |a GBV_ILN_32 
912 |a GBV_ILN_39 
912 |a GBV_ILN_40 
912 |a GBV_ILN_60 
912 |a GBV_ILN_62 
912 |a GBV_ILN_63 
912 |a GBV_ILN_65 
912 |a GBV_ILN_69 
912 |a GBV_ILN_70 
912 |a GBV_ILN_73 
912 |a GBV_ILN_74 
912 |a GBV_ILN_90 
912 |a GBV_ILN_95 
912 |a GBV_ILN_100 
912 |a GBV_ILN_105 
912 |a GBV_ILN_110 
912 |a GBV_ILN_120 
912 |a GBV_ILN_138 
912 |a GBV_ILN_150 
912 |a GBV_ILN_151 
912 |a GBV_ILN_161 
912 |a GBV_ILN_170 
912 |a GBV_ILN_171 
912 |a GBV_ILN_187 
912 |a GBV_ILN_213 
912 |a GBV_ILN_224 
912 |a GBV_ILN_230 
912 |a GBV_ILN_266 
912 |a GBV_ILN_285 
912 |a GBV_ILN_293 
912 |a GBV_ILN_370 
912 |a GBV_ILN_374 
912 |a GBV_ILN_602 
912 |a GBV_ILN_636 
912 |a GBV_ILN_702 
912 |a GBV_ILN_2001 
912 |a GBV_ILN_2003 
912 |a GBV_ILN_2004 
912 |a GBV_ILN_2005 
912 |a GBV_ILN_2006 
912 |a GBV_ILN_2007 
912 |a GBV_ILN_2008 
912 |a GBV_ILN_2009 
912 |a GBV_ILN_2010 
912 |a GBV_ILN_2011 
912 |a GBV_ILN_2014 
912 |a GBV_ILN_2015 
912 |a GBV_ILN_2018 
912 |a GBV_ILN_2020 
912 |a GBV_ILN_2021 
912 |a GBV_ILN_2025 
912 |a GBV_ILN_2026 
912 |a GBV_ILN_2027 
912 |a GBV_ILN_2034 
912 |a GBV_ILN_2037 
912 |a GBV_ILN_2038 
912 |a GBV_ILN_2044 
912 |a GBV_ILN_2048 
912 |a GBV_ILN_2049 
912 |a GBV_ILN_2050 
912 |a GBV_ILN_2055 
912 |a GBV_ILN_2056 
912 |a GBV_ILN_2057 
912 |a GBV_ILN_2059 
912 |a GBV_ILN_2061 
912 |a GBV_ILN_2064 
912 |a GBV_ILN_2068 
912 |a GBV_ILN_2088 
912 |a GBV_ILN_2093 
912 |a GBV_ILN_2106 
912 |a GBV_ILN_2107 
912 |a GBV_ILN_2108 
912 |a GBV_ILN_2110 
912 |a GBV_ILN_2111 
912 |a GBV_ILN_2113 
912 |a GBV_ILN_2118 
912 |a GBV_ILN_2119 
912 |a GBV_ILN_2122 
912 |a GBV_ILN_2129 
912 |a GBV_ILN_2143 
912 |a GBV_ILN_2144 
912 |a GBV_ILN_2147 
912 |a GBV_ILN_2148 
912 |a GBV_ILN_2152 
912 |a GBV_ILN_2153 
912 |a GBV_ILN_2188 
912 |a GBV_ILN_2190 
912 |a GBV_ILN_2232 
912 |a GBV_ILN_2336 
912 |a GBV_ILN_2470 
912 |a GBV_ILN_2472 
912 |a GBV_ILN_2507 
912 |a GBV_ILN_2522 
912 |a GBV_ILN_2548 
912 |a GBV_ILN_2939 
912 |a GBV_ILN_2946 
912 |a GBV_ILN_2949 
912 |a GBV_ILN_2951 
912 |a GBV_ILN_4012 
912 |a GBV_ILN_4035 
912 |a GBV_ILN_4037 
912 |a GBV_ILN_4046 
912 |a GBV_ILN_4112 
912 |a GBV_ILN_4125 
912 |a GBV_ILN_4126 
912 |a GBV_ILN_4242 
912 |a GBV_ILN_4246 
912 |a GBV_ILN_4249 
912 |a GBV_ILN_4251 
912 |a GBV_ILN_4305 
912 |a GBV_ILN_4306 
912 |a GBV_ILN_4307 
912 |a GBV_ILN_4313 
912 |a GBV_ILN_4322 
912 |a GBV_ILN_4323 
912 |a GBV_ILN_4324 
912 |a GBV_ILN_4325 
912 |a GBV_ILN_4326 
912 |a GBV_ILN_4333 
912 |a GBV_ILN_4334 
912 |a GBV_ILN_4335 
912 |a GBV_ILN_4336 
912 |a GBV_ILN_4338 
912 |a GBV_ILN_4346 
912 |a GBV_ILN_4393 
912 |a GBV_ILN_4700 
951 |a AR 
952 |d 77  |j 2005  |e 7  |h 3066-3073