High-pressure X-ray photon correlation spectroscopy at fourth-generation synchrotron sources

open access.

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 31(2024), Pt 3 vom: 01. Mai, Seite 527-539
1. Verfasser: Cornet, Antoine (VerfasserIn)
Weitere Verfasser: Ronca, Alberto, Shen, Jie, Zontone, Federico, Chushkin, Yuriy, Cammarata, Marco, Garbarino, Gaston, Sprung, Michael, Westermeier, Fabian, Deschamps, Thierry, Ruta, Beatrice
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2024
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article X-ray photon correlation spectroscopy complex systems fourth-generation synchrotron sources high-pressure XPCS high-pressure sample environments metallic glasses supercooled liquid states
LEADER 01000caa a22002652 4500
001 NLM370870794
003 DE-627
005 20250104233629.0
007 cr uuu---uuuuu
008 240410s2024 xx |||||o 00| ||eng c
024 7 |a 10.1107/S1600577524001784  |2 doi 
028 5 2 |a pubmed24n1651.xml 
035 |a (DE-627)NLM370870794 
035 |a (NLM)38597746 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Cornet, Antoine  |e verfasserin  |4 aut 
245 1 0 |a High-pressure X-ray photon correlation spectroscopy at fourth-generation synchrotron sources 
264 1 |c 2024 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 04.01.2025 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a open access. 
520 |a A new experimental setup combining X-ray photon correlation spectroscopy (XPCS) in the hard X-ray regime and a high-pressure sample environment has been developed to monitor the pressure dependence of the internal motion of complex systems down to the atomic scale in the multi-gigapascal range, from room temperature to 600 K. The high flux of coherent high-energy X-rays at fourth-generation synchrotron sources solves the problems caused by the absorption of diamond anvil cells used to generate high pressure, enabling the measurement of the intermediate scattering function over six orders of magnitude in time, from 10-3 s to 103 s. The constraints posed by the high-pressure generation such as the preservation of X-ray coherence, as well as the sample, pressure and temperature stability, are discussed, and the feasibility of high-pressure XPCS is demonstrated through results obtained on metallic glasses 
650 4 |a Journal Article 
650 4 |a X-ray photon correlation spectroscopy 
650 4 |a complex systems 
650 4 |a fourth-generation synchrotron sources 
650 4 |a high-pressure XPCS 
650 4 |a high-pressure sample environments 
650 4 |a metallic glasses 
650 4 |a supercooled liquid states 
700 1 |a Ronca, Alberto  |e verfasserin  |4 aut 
700 1 |a Shen, Jie  |e verfasserin  |4 aut 
700 1 |a Zontone, Federico  |e verfasserin  |4 aut 
700 1 |a Chushkin, Yuriy  |e verfasserin  |4 aut 
700 1 |a Cammarata, Marco  |e verfasserin  |4 aut 
700 1 |a Garbarino, Gaston  |e verfasserin  |4 aut 
700 1 |a Sprung, Michael  |e verfasserin  |4 aut 
700 1 |a Westermeier, Fabian  |e verfasserin  |4 aut 
700 1 |a Deschamps, Thierry  |e verfasserin  |4 aut 
700 1 |a Ruta, Beatrice  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 31(2024), Pt 3 vom: 01. Mai, Seite 527-539  |w (DE-627)NLM09824129X  |x 1600-5775  |7 nnns 
773 1 8 |g volume:31  |g year:2024  |g number:Pt 3  |g day:01  |g month:05  |g pages:527-539 
856 4 0 |u http://dx.doi.org/10.1107/S1600577524001784  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 31  |j 2024  |e Pt 3  |b 01  |c 05  |h 527-539