Augmented intramedullary screw tension band construct for olecranon fracture reduction and fixation : a review of literature and surgical technique

© 2020 The Author(s).

Détails bibliographiques
Publié dans:JSES international. - 2020. - 4(2020), 3 vom: 25. Sept., Seite 470-477
Auteur principal: Labrum, Joseph T 4th (Auteur)
Autres auteurs: Foster, Brock D, Weikert, Douglas R
Format: Article en ligne
Langue:English
Publié: 2020
Accès à la collection:JSES international
Sujets:Journal Article Olecranon fracture intramedullary lag screw tension band wiring trauma upper extremity
LEADER 01000caa a22002652c 4500
001 NLM315110171
003 DE-627
005 20250228004121.0
007 cr uuu---uuuuu
008 231225s2020 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jseint.2020.04.005  |2 doi 
028 5 2 |a pubmed25n1050.xml 
035 |a (DE-627)NLM315110171 
035 |a (NLM)32939470 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Labrum, Joseph T  |c 4th  |e verfasserin  |4 aut 
245 1 0 |a Augmented intramedullary screw tension band construct for olecranon fracture reduction and fixation  |b a review of literature and surgical technique 
264 1 |c 2020 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Revised 28.09.2020 
500 |a published: Electronic-eCollection 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a © 2020 The Author(s). 
520 |a Olecranon fractures, which make up 10% of upper extremity fractures in adults, often require anatomic reduction and stable internal fixation. Successful olecranon fracture osteosynthesis has classically been achieved via tension band wiring or plate fixation. This article reviews the indications, outcomes, and a surgical technique as an alternative construct for tension band wiring of olecranon fractures. The technique involves placement of an ulnar intramedullary partially threaded screw that is used as a proximal point of attachment for tension band wiring of the olecranon. Although infrequently used by orthopedic surgeons, this construct has been shown to be biomechanically and clinically superior to classic Kirschner wire tension banding techniques. This review is intended to familiarize surgeons with a surgical technique that can be applied to a variety of proximal ulna fractures 
650 4 |a Journal Article 
650 4 |a Olecranon fracture 
650 4 |a intramedullary 
650 4 |a lag screw 
650 4 |a tension band wiring 
650 4 |a trauma 
650 4 |a upper extremity 
700 1 |a Foster, Brock D  |e verfasserin  |4 aut 
700 1 |a Weikert, Douglas R  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t JSES international  |d 2020  |g 4(2020), 3 vom: 25. Sept., Seite 470-477  |w (DE-627)NLM307818438  |x 2666-6383  |7 nnas 
773 1 8 |g volume:4  |g year:2020  |g number:3  |g day:25  |g month:09  |g pages:470-477 
856 4 0 |u http://dx.doi.org/10.1016/j.jseint.2020.04.005  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_50 
912 |a GBV_ILN_65 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 4  |j 2020  |e 3  |b 25  |c 09  |h 470-477