Radio frequency catheter ablation of arrhythmias with low dose X-ray guided by three-dimensional mapping system in 14 children

Objective: To assess the feasibility and efficacy of radiofrequency catheter ablation (RFCA) of arrhythmias with low dose X-ray in children guided by three-dimensional mapping system. Methods: Fourteen children with tachyarrhythmia who were transferred to Tianjin Medical University General Hospital...

Description complète

Détails bibliographiques
Publié dans:Zhonghua er ke za zhi = Chinese journal of pediatrics. - 1960. - 58(2020), 7 vom: 02. Juli, Seite 576-580
Auteur principal: Deng, J G (Auteur)
Autres auteurs: Zheng, H M, Cai, H, Xing, S H, Wang, M
Format: Article en ligne
Langue:Chinese
Publié: 2020
Accès à la collection:Zhonghua er ke za zhi = Chinese journal of pediatrics
Sujets:Journal Article Catheter ablation Child Tachycardia