Compact undulator line for a high-brilliance soft-X-ray free-electron laser at MAX IV
The optimal parameter space for an X-ray free-electron laser (FEL) in the self-amplified spontaneous emission (SASE) operation mode is examined. This study focuses on FEL operation with a shorter undulator period and higher undulator strength made available through recent developments in in-vacuum,...
| Veröffentlicht in: | Journal of synchrotron radiation. - 1994. - 26(2019), Pt 3 vom: 01. Mai, Seite 891-898 |
|---|---|
| 1. Verfasser: | |
| Weitere Verfasser: | , |
| Format: | Online-Aufsatz |
| Sprache: | English |
| Veröffentlicht: |
2019
|
| Zugriff auf das übergeordnete Werk: | Journal of synchrotron radiation |
| Schlagworte: | Journal Article X-ray free-electron lasers harmonic lasing self-seeding high brilliance self-amplified spontaneous emission undulator technologies |
| Zusammenfassung: | The optimal parameter space for an X-ray free-electron laser (FEL) in the self-amplified spontaneous emission (SASE) operation mode is examined. This study focuses on FEL operation with a shorter undulator period and higher undulator strength made available through recent developments in in-vacuum, cryogenic and superconducting undulators. Progress on short-period undulator technologies is surveyed and FEL output characteristics versus undulator parameters are computed. The study is performed on a case of the planned soft-X-ray FEL at the MAX IV Laboratory in Sweden. An extension of the SASE mode into the harmonic lasing self-seeded mode is also analysed |
|---|---|
| Beschreibung: | Date Revised 20.11.2019 published: Print-Electronic Citation Status PubMed-not-MEDLINE |
| ISSN: | 1600-5775 |
| DOI: | 10.1107/S160057751900290X |