Sulfide emissions in sewer networks : focus on liquid to gas mass transfer coefficient

H2S emission dynamics in sewers are conditioned by the mass transfer coefficient at the interface. This work aims at measuring the variation of the mass transfer coefficient with the hydraulic characteristics, with the objective of estimating H2S emission in gravity pipes, and collecting data to est...

Description complète

Détails bibliographiques
Publié dans:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 75(2017), 7-8 vom: 01. Apr., Seite 1899-1908
Auteur principal: Carrera, Lucie (Auteur)
Autres auteurs: Springer, Fanny, Lipeme-Kouyi, Gislain, Buffiere, Pierre
Format: Article en ligne
Langue:English
Publié: 2017
Accès à la collection:Water science and technology : a journal of the International Association on Water Pollution Research
Sujets:Journal Article Gases Sewage Sulfides Water Pollutants, Chemical
Description
Résumé:H2S emission dynamics in sewers are conditioned by the mass transfer coefficient at the interface. This work aims at measuring the variation of the mass transfer coefficient with the hydraulic characteristics, with the objective of estimating H2S emission in gravity pipes, and collecting data to establish models independent of the system geometry. The ratio between the H2S and O2 mass transfer coefficient was assessed in an 8 L mixed reactor under different experimental conditions. Then, oxygen mass transfer measurements were performed in a 10 m long gravity pipe. The following ranges of experimental conditions were investigated: velocity flow [0-0.61 m.s-1], Reynolds number [0-23,333]. The hydrodynamic parameters at the liquid/gas interface were calculated by computational fluid dynamics (CFD). In the laboratory-scale reactor, the O2 mass transfer coefficient was found to depend on the stirring rate (rph) as follows: KL,O2 = 0.016 + 0.025 N3.85. A KL,H2S/KL,O2 ratio of 0.64 ± 0.24 was found, in accordance with previously published data. CFD results helped in refining this correlation: the mass transfer coefficient depends on the local interface velocity ui (m.h-1): KL,O2 = 0.016 + 1.02 × 10-5 ui3.85 In the gravity pipe device, KL,O2 also exponentially increased with the mean flow velocity. These trends were found to be consistent with the increasing level of turbulence
Description:Date Completed 19.09.2017
Date Revised 02.12.2018
published: Print
Citation Status MEDLINE
ISSN:0273-1223