|
|
|
|
| LEADER |
01000caa a22002652c 4500 |
| 001 |
NLM221504915 |
| 003 |
DE-627 |
| 005 |
20250214115447.0 |
| 007 |
cr uuu---uuuuu |
| 008 |
231224s2012 xx |||||o 00| ||eng c |
| 024 |
7 |
|
|a 10.2144/0000113902
|2 doi
|
| 028 |
5 |
2 |
|a pubmed25n0738.xml
|
| 035 |
|
|
|a (DE-627)NLM221504915
|
| 035 |
|
|
|a (NLM)23030060
|
| 040 |
|
|
|a DE-627
|b ger
|c DE-627
|e rakwb
|
| 041 |
|
|
|a eng
|
| 100 |
1 |
|
|a Tanner, Nathan A
|e verfasserin
|4 aut
|
| 245 |
1 |
0 |
|a Simultaneous multiple target detection in real-time loop-mediated isothermal amplification
|
| 264 |
|
1 |
|c 2012
|
| 336 |
|
|
|a Text
|b txt
|2 rdacontent
|
| 337 |
|
|
|a ƒaComputermedien
|b c
|2 rdamedia
|
| 338 |
|
|
|a ƒa Online-Ressource
|b cr
|2 rdacarrier
|
| 500 |
|
|
|a Date Completed 10.12.2012
|
| 500 |
|
|
|a Date Revised 10.12.2019
|
| 500 |
|
|
|a published: Print
|
| 500 |
|
|
|a Citation Status MEDLINE
|
| 520 |
|
|
|a Loop-mediated isothermal amplification (LAMP) is a rapid and reliable sequence-specific isothermal nucleic acid amplification technique. To date, all reported real-time detection methods for LAMP have been restricted to single targets, limiting the utility of this technique. Here, we adapted standard LAMP primers to contain a quencher-fluorophore duplex region that upon strand separation results in a gain of fluorescent signal. This approach permitted the real-time detection of 1-4 target sequences in a single LAMP reaction tube utilizing a standard real-time fluorimeter. The methodology was highly reproducible and sensitive, detecting below 100 copies of human genomic DNA. It was also robust, with a 7-order of magnitude dynamic range of detectable targets. Furthermore, using a new strand-displacing DNA polymerase or its warm-start version, Bst 2.0 or Bst 2.0 WarmStart DNA polymerases, resulted in 50% faster amplification signals than wild-type Bst DNA polymerase, large fragment in this new multiplex LAMP procedure. The coupling of this new multiplex technique with next generation isothermal DNA polymerases should increase the utility of the LAMP method for molecular diagnostics
|
| 650 |
|
4 |
|a Evaluation Study
|
| 650 |
|
4 |
|a Journal Article
|
| 650 |
|
4 |
|a Research Support, Non-U.S. Gov't
|
| 650 |
|
7 |
|a DNA Primers
|2 NLM
|
| 650 |
|
7 |
|a Fluorescent Dyes
|2 NLM
|
| 650 |
|
7 |
|a DNA
|2 NLM
|
| 650 |
|
7 |
|a 9007-49-2
|2 NLM
|
| 650 |
|
7 |
|a DNA-Directed DNA Polymerase
|2 NLM
|
| 650 |
|
7 |
|a EC 2.7.7.7
|2 NLM
|
| 700 |
1 |
|
|a Zhang, Yinhua
|e verfasserin
|4 aut
|
| 700 |
1 |
|
|a Evans, Thomas C
|c Jr
|e verfasserin
|4 aut
|
| 773 |
0 |
8 |
|i Enthalten in
|t BioTechniques
|d 1991
|g 53(2012), 2 vom: 23. Aug., Seite 81-9
|w (DE-627)NLM012627046
|x 1940-9818
|7 nnas
|
| 773 |
1 |
8 |
|g volume:53
|g year:2012
|g number:2
|g day:23
|g month:08
|g pages:81-9
|
| 856 |
4 |
0 |
|u http://dx.doi.org/10.2144/0000113902
|3 Volltext
|
| 912 |
|
|
|a GBV_USEFLAG_A
|
| 912 |
|
|
|a SYSFLAG_A
|
| 912 |
|
|
|a GBV_NLM
|
| 912 |
|
|
|a GBV_ILN_21
|
| 912 |
|
|
|a GBV_ILN_22
|
| 912 |
|
|
|a GBV_ILN_24
|
| 912 |
|
|
|a GBV_ILN_39
|
| 912 |
|
|
|a GBV_ILN_40
|
| 912 |
|
|
|a GBV_ILN_50
|
| 912 |
|
|
|a GBV_ILN_60
|
| 912 |
|
|
|a GBV_ILN_62
|
| 912 |
|
|
|a GBV_ILN_65
|
| 912 |
|
|
|a GBV_ILN_70
|
| 912 |
|
|
|a GBV_ILN_99
|
| 912 |
|
|
|a GBV_ILN_121
|
| 912 |
|
|
|a GBV_ILN_130
|
| 912 |
|
|
|a GBV_ILN_227
|
| 912 |
|
|
|a GBV_ILN_350
|
| 912 |
|
|
|a GBV_ILN_618
|
| 912 |
|
|
|a GBV_ILN_640
|
| 912 |
|
|
|a GBV_ILN_754
|
| 912 |
|
|
|a GBV_ILN_2001
|
| 912 |
|
|
|a GBV_ILN_2002
|
| 912 |
|
|
|a GBV_ILN_2003
|
| 912 |
|
|
|a GBV_ILN_2005
|
| 912 |
|
|
|a GBV_ILN_2006
|
| 912 |
|
|
|a GBV_ILN_2007
|
| 912 |
|
|
|a GBV_ILN_2008
|
| 912 |
|
|
|a GBV_ILN_2009
|
| 912 |
|
|
|a GBV_ILN_2010
|
| 912 |
|
|
|a GBV_ILN_2012
|
| 912 |
|
|
|a GBV_ILN_2015
|
| 912 |
|
|
|a GBV_ILN_2018
|
| 912 |
|
|
|a GBV_ILN_2023
|
| 912 |
|
|
|a GBV_ILN_2035
|
| 912 |
|
|
|a GBV_ILN_2040
|
| 912 |
|
|
|a GBV_ILN_2060
|
| 912 |
|
|
|a GBV_ILN_2099
|
| 912 |
|
|
|a GBV_ILN_2105
|
| 912 |
|
|
|a GBV_ILN_2121
|
| 912 |
|
|
|a GBV_ILN_2470
|
| 951 |
|
|
|a AR
|
| 952 |
|
|
|d 53
|j 2012
|e 2
|b 23
|c 08
|h 81-9
|