Study of micro-channel geometries for internally cooled Si monochromators

Rocking curves of micro-channel (MC) water-cooled monochromators are broadened by stresses introduced during fabrication and under X-ray thermal load. This is a problem which will be even more serious with the rise of the fourth-generation synchrotron sources, i.e. the free-electron lasers. The X-ra...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1994. - 15(2008), Pt 6 vom: 11. Nov., Seite 543-8
1. Verfasser: Oberta, P (VerfasserIn)
Weitere Verfasser: Ac, V, Hrdý, J, Lukás, B
Format: Online-Aufsatz
Sprache:English
Veröffentlicht: 2008
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article Research Support, Non-U.S. Gov't Silicon Z4152N8IUI
LEADER 01000caa a22002652 4500
001 NLM184008824
003 DE-627
005 20250209212008.0
007 cr uuu---uuuuu
008 231223s2008 xx |||||o 00| ||eng c
024 7 |a 10.1107/S0909049508027374  |2 doi 
028 5 2 |a pubmed25n0613.xml 
035 |a (DE-627)NLM184008824 
035 |a (NLM)18955759 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Oberta, P  |e verfasserin  |4 aut 
245 1 0 |a Study of micro-channel geometries for internally cooled Si monochromators 
264 1 |c 2008 
336 |a Text  |b txt  |2 rdacontent 
337 |a ƒaComputermedien  |b c  |2 rdamedia 
338 |a ƒa Online-Ressource  |b cr  |2 rdacarrier 
500 |a Date Completed 08.01.2009 
500 |a Date Revised 21.11.2013 
500 |a published: Print-Electronic 
500 |a Citation Status MEDLINE 
520 |a Rocking curves of micro-channel (MC) water-cooled monochromators are broadened by stresses introduced during fabrication and under X-ray thermal load. This is a problem which will be even more serious with the rise of the fourth-generation synchrotron sources, i.e. the free-electron lasers. The X-ray optics group at the Institute of Physics at the ASCR v.v.i. in Prague is designing, testing and, with company Polovodice a.s., fabricating novel internally water-cooled Si monochromators. Here three new micro-channel geometries are introduced which reduce rocking-curve enlargement owing to the fabrication to less than 2.5 microrad ( approximately 0.5 arcsec). All three MC designs show less rocking-curve enlargement and smoother topographic images. The designs also show better cooling efficiencies than the classical MC design in finite-element analysis calculations 
650 4 |a Journal Article 
650 4 |a Research Support, Non-U.S. Gov't 
650 7 |a Silicon  |2 NLM 
650 7 |a Z4152N8IUI  |2 NLM 
700 1 |a Ac, V  |e verfasserin  |4 aut 
700 1 |a Hrdý, J  |e verfasserin  |4 aut 
700 1 |a Lukás, B  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1994  |g 15(2008), Pt 6 vom: 11. Nov., Seite 543-8  |w (DE-627)NLM09824129X  |x 0909-0495  |7 nnns 
773 1 8 |g volume:15  |g year:2008  |g number:Pt 6  |g day:11  |g month:11  |g pages:543-8 
856 4 0 |u http://dx.doi.org/10.1107/S0909049508027374  |3 Volltext 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 15  |j 2008  |e Pt 6  |b 11  |c 11  |h 543-8