X-ray beam-position monitoring in the sub-micrometre and sub-second regime

It is demonstrated that X-ray beam positions can be extracted from two-dimensional profiles with sub-pixel resolution. Beam-position measurements utilizing a self-designed low-cost two-dimensional detector have been performed at two synchrotron radiation beamlines of the Swiss Light Source. The effe...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Journal of synchrotron radiation. - 1998. - 12(2005), Pt 6 vom: 22. Nov., Seite 795-9
1. Verfasser: Bunk, Oliver (VerfasserIn)
Weitere Verfasser: Pfeiffer, Franz, Stampanoni, Marco, Patterson, Bruce D, Schulze-Briese, Clemens, David, Christian
Format: Aufsatz
Sprache:English
Veröffentlicht: 2005
Zugriff auf das übergeordnete Werk:Journal of synchrotron radiation
Schlagworte:Journal Article
LEADER 01000caa a22002652 4500
001 NLM158489403
003 DE-627
005 20250206192152.0
007 tu
008 231223s2005 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0528.xml 
035 |a (DE-627)NLM158489403 
035 |a (NLM)16239750 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a Bunk, Oliver  |e verfasserin  |4 aut 
245 1 0 |a X-ray beam-position monitoring in the sub-micrometre and sub-second regime 
264 1 |c 2005 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 17.01.2006 
500 |a Date Revised 21.10.2005 
500 |a published: Print-Electronic 
500 |a Citation Status PubMed-not-MEDLINE 
520 |a It is demonstrated that X-ray beam positions can be extracted from two-dimensional profiles with sub-pixel resolution. Beam-position measurements utilizing a self-designed low-cost two-dimensional detector have been performed at two synchrotron radiation beamlines of the Swiss Light Source. The effective detector pixel size was 4.8 microm and the resolution achieved for the beam position was about 5 nm. At a data rate of 25 frames per second, periodic variations of the beam position could be detected with a frequency resolution below 0.1 Hz. This allowed, for example, the influence of a turbo-pump in the X-ray optics hutch on the beam position to be quantified, and even minute variations related to the electron beam in the storage ring could be detected 
650 4 |a Journal Article 
700 1 |a Pfeiffer, Franz  |e verfasserin  |4 aut 
700 1 |a Stampanoni, Marco  |e verfasserin  |4 aut 
700 1 |a Patterson, Bruce D  |e verfasserin  |4 aut 
700 1 |a Schulze-Briese, Clemens  |e verfasserin  |4 aut 
700 1 |a David, Christian  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Journal of synchrotron radiation  |d 1998  |g 12(2005), Pt 6 vom: 22. Nov., Seite 795-9  |w (DE-627)NLM09824129X  |x 0909-0495  |7 nnns 
773 1 8 |g volume:12  |g year:2005  |g number:Pt 6  |g day:22  |g month:11  |g pages:795-9 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_40 
912 |a GBV_ILN_350 
912 |a GBV_ILN_2005 
951 |a AR 
952 |d 12  |j 2005  |e Pt 6  |b 22  |c 11  |h 795-9