Removal of struvite to prevent problems associated with its accumulation in wastewater treatment works

Deposition of struvite within the infrastructure of wastewater treatment works can cause significant operating difficulties. A laboratory-scale, two-stage, continuously stirred tank reactor was developed to remove struvite to prevent problems associated with its deposition. Before any experimental w...

Description complète

Détails bibliographiques
Publié dans:Water environment research : a research publication of the Water Environment Federation. - 1998. - 76(2004), 5 vom: 05. Sept., Seite 437-43
Auteur principal: Stratful, I (Auteur)
Autres auteurs: Scrimshaw, M D, Lester, J N
Format: Article
Langue:English
Publié: 2004
Accès à la collection:Water environment research : a research publication of the Water Environment Federation
Sujets:Journal Article Research Support, Non-U.S. Gov't Magnesium Compounds Phosphates Struvite AW3EJL1462 Magnesium I38ZP9992A