Start-up of a pilot-scale anaerobic fixed film reactor at low temperature treating slaughterhouse wastewater

A pilot-scale anaerobic fixed film reactor (AFFR) with vertically arranged PVC tubes as biomass carrier, treating poultry slaughterhouse wastewater was started-up in 74 days at temperatures between 20-24 degrees C. The start-up process consisted of a long acclimatization phase followed by a low load...

Ausführliche Beschreibung

Bibliographische Detailangaben
Veröffentlicht in:Water science and technology : a journal of the International Association on Water Pollution Research. - 1986. - 46(2002), 4-5 vom: 25., Seite 215-21
1. Verfasser: del Pozo, R (VerfasserIn)
Weitere Verfasser: Diez, V, Salazar, G
Format: Aufsatz
Sprache:English
Veröffentlicht: 2002
Zugriff auf das übergeordnete Werk:Water science and technology : a journal of the International Association on Water Pollution Research
Schlagworte:Journal Article Organic Chemicals
LEADER 01000caa a22002652 4500
001 NLM121525171
003 DE-627
005 20250203130838.0
007 tu
008 231222s2002 xx ||||| 00| ||eng c
028 5 2 |a pubmed25n0405.xml 
035 |a (DE-627)NLM121525171 
035 |a (NLM)12361013 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
100 1 |a del Pozo, R  |e verfasserin  |4 aut 
245 1 0 |a Start-up of a pilot-scale anaerobic fixed film reactor at low temperature treating slaughterhouse wastewater 
264 1 |c 2002 
336 |a Text  |b txt  |2 rdacontent 
337 |a ohne Hilfsmittel zu benutzen  |b n  |2 rdamedia 
338 |a Band  |b nc  |2 rdacarrier 
500 |a Date Completed 06.02.2003 
500 |a Date Revised 14.11.2003 
500 |a published: Print 
500 |a Citation Status MEDLINE 
520 |a A pilot-scale anaerobic fixed film reactor (AFFR) with vertically arranged PVC tubes as biomass carrier, treating poultry slaughterhouse wastewater was started-up in 74 days at temperatures between 20-24 degrees C. The start-up process consisted of a long acclimatization phase followed by a low loaded growth phase, a gradual increase of OLR upto 9.2 kg COD/m3d, and a final maturation phase at moderated loads of 2.7 kg COD/m3d at which total COD removal efficiencies of 57% were achieved. Alkalinity ratio IA:PA was found to be the best control parameter to avoid VFA accumulation. OLR increase based on pH control was not satisfactory because changes in CO2 solubility caused daily by temperature and flow variations led to pH oscillations of 0.2 units. The low wastewater alkalinity, 260 mg/l CaCO3 was insufficient to buffer the pH system, therefore the pH decrease associated with the VFA accumulation was not easily detected and could not be used as a way of OLR control. Organic matter removal took place by accumulation and biodegradation processes. Limitation in the reactor hydrodynamics and particulate fraction hydrolysis was detected at high flow rates 
650 4 |a Journal Article 
650 7 |a Organic Chemicals  |2 NLM 
700 1 |a Diez, V  |e verfasserin  |4 aut 
700 1 |a Salazar, G  |e verfasserin  |4 aut 
773 0 8 |i Enthalten in  |t Water science and technology : a journal of the International Association on Water Pollution Research  |d 1986  |g 46(2002), 4-5 vom: 25., Seite 215-21  |w (DE-627)NLM098149431  |x 0273-1223  |7 nnns 
773 1 8 |g volume:46  |g year:2002  |g number:4-5  |g day:25  |g pages:215-21 
912 |a GBV_USEFLAG_A 
912 |a SYSFLAG_A 
912 |a GBV_NLM 
912 |a GBV_ILN_350 
951 |a AR 
952 |d 46  |j 2002  |e 4-5  |b 25  |h 215-21